IECC 2018
Idioma: Inglés Series The International CodesCountry Club Hills, IL International Code Council 2017Edición: August 31, 2017Descripción: xii, various pages: charts 28 cmTipo de contenido:- text
- unmediaded
- volume
- 9781609837495
- International Energy Conservation Code 2018
- 2018 International Energy Conservation Code
- International Codes 2018
- 696
- K3840 I58 2017
| Imagen de cubierta | Tipo de ítem | Biblioteca actual | Biblioteca de origen | Colección | Ubicación en estantería | Signatura topográfica | Materiales especificados | Info Vol | URL | Copia número | Estado | Notas | Fecha de vencimiento | Código de barras | Reserva de ítems | Prioridad de la cola de reserva de ejemplar | Reservas para cursos | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Libro Referencia CARIBET | CARIBET Biblioteca Arquitectura Colección de Referencia CARIBET | Rererencia K3840 I58 2017 (Navegar estantería(Abre debajo)) | 1 | Disponible | 91000000057430 |
Navegando CARIBET Biblioteca Arquitectura estanterías,Ubicación en estantería: Colección de Referencia CARIBET Cerrar el navegador de estanterías (Oculta el navegador de estanterías)
|
|
|
|
No hay imagen de cubierta disponible No hay imagen de cubierta disponible | No hay imagen de cubierta disponible No hay imagen de cubierta disponible |
|
||
| Referencia KF5708 I58 2017 IMC 2018 | Referencia KF3816.S49 I58 2017 IPSDC 2018 | Referencia KF5704 I58 2017 IFGC 2018 | Rererencia K3840 I58 2017 IECC 2018 | Referencia QH75 B468 2008 Zonas de amortiguamiento para conservacion | Referencia HN49.C6 C677 1998 Manejo de recuperación del espacio público estudio de caso carrera 15, de la calle 72 a la 100 | Referencia AY67.N5 W7 2011 The World almanac and book of facts : txt 2018. / |
Descripciones mejoradas de Syndetics:
The IECC addresses energy efficiency on several fronts including cost savings, reduced energy usage, conservation of natural resources and the impact of energy usage on the environment. Key changes include: Log homes designed in accordance with the standard ICC 400, Standards on the Design and Construction of Log Structures, are exempt from the building thermal envelope requirements of the IECC. The maximum allowable fenestration U-factors in Table R402.1.2 (for the prescriptive compliance path) for climates zones 3 through 8 have been reduced from the values in the 2015 edition. The ICC/RESNET 380 standard has been included as one of standards that can be used for determining the air leakage rate of a building or dwelling unit. The Energy Rating Index compliance alternative index values have been increased slightly however, the method for determining an index is now required to be in accordance with standard ICC/RESNET 301. Revisions to interior and exterior lighting power budgets and better clarity for lighting controls. Clarity that regardless of design methodology, system commissioning is required. New limits on heated or cooled vestibules. Mechanical provisions reorganized based on equipment type rather than design methodology.
Includes index.