000 20174nam a22003737a 4500
003 pucpr
005 20250508123036.0
008 160222s2021 ad fr 001 0 eng
020 _a9781609839574
_qsoft-cover edition
020 _a9781609839581
_qloose-leaf edition
040 _apucpr
_benglish
_erda
_cpucpr
_dpucpr
041 0 _aeng
049 _aCARIBET
050 0 0 _aKF5701.A73
_bI58 2021
110 2 _9297410
_aInternational Code Council
245 1 0 _aIRC 2021 :
_bInternational Residential code for a One- and Two-Family Dwellings
_htxt
246 3 _a2021 International residential Code for one-and two-family dwellings
246 3 _aInternational residential Code 2021
246 3 _a2021 International Codes
250 _aJanuary 29, 2021
264 _aCountry Club Hills, IL
_bInternational Code Council
_c2021
300 _axxx, various pages
_bill., ill.; charts
_c28 cm.
_fbook
336 _2rdacontent
_btxt
_atext
337 _2rdamedia
_bn
_aunmediaded
338 _2rdacarrier
_bnc
_avolume
440 _9296229
_aThe International Codes
_n2021
500 _aIncludes index.
504 _aIncludes index.
505 _aPart I—Administrative -- CHAPTER 1 SCOPE AND ADMINISTRATION -- PART 1—SCOPE AND APPLICATION -- R101 Scope and General Requirements -- R102 Applicability -- PART 2—ADMINISTRATION AND ENFORCEMENT -- R103 Department of Building Safety -- R104 Duties and Powers of the Building Official -- R105 Permits -- R106 Construction Documents -- R107 Temporary Structures and Uses -- R108 Fees -- R109 Inspections -- R110 Certificate of Occupancy -- R111 Service Utilities -- R112 Board of Appeals -- R113 Violations -- R114 Stop Work Order -- Part II—Definitions -- CHAPTER 2 DEFINITIONS -- R201 General -- R202 Definitions -- Part III—Building Planning and Construction -- CHAPTER 3 BUILDING PLANNING -- R301 Design Criteria -- R302 Fire-resistant Construction -- R303 Light, Ventilation and Heating -- R304 Minimum Room Areas -- R305 Ceiling Height -- R306 Sanitation -- R307 Toilet, Bath and Shower Spaces -- R308 Glazing -- R309 Garages and Carports -- R310 Emergency Escape and Rescue Openings -- R311 Means of Egress -- R312 Guards and Window Fall Protection -- R313 Automatic Fire Sprinkler Systems -- R314 Smoke Alarms -- R315 Carbon Monoxide Alarms -- R316 Foam Plastic -- R317 Protection of Wood and Wood-based Products against Decay -- R318 Protection against Subterranean Termites -- R319 Site Address -- R320 Accessibility -- R321 Elevators and Platform Lifts -- R322 Flood-resistant Construction -- R323 Storm Shelters -- R324 Solar Energy Systems -- R325 Mezzanines -- R326 Habitable Attics -- R327 Swimming Pools, Spas and Hot Tubs -- R328 Energy Storage Systems -- R329 Stationary Engine Generators -- R330 Stationary Fuel Cell Power Systems -- CHAPTER 4 FOUNDATIONS -- R401 General -- R402 Materials -- R403 Footings -- R404 Foundation and Retaining Walls -- R405 Foundation Drainage -- R406 Foundation Waterproofing and Dampproofing -- R407 Columns -- R408 Under-floor Space -- CHAPTER 5 FLOORS -- R501 General -- R502 Wood Floor Framing -- R503 Floor Sheathing -- R504 Pressure Preservative-treated Wood Floors (On Ground) -- R505 Cold-formed Steel Floor Framing -- R506 Concrete Floors (On Ground) -- R507 Exterior Decks -- CHAPTER 6 WALL CONSTRUCTION -- R601 General -- R602 Wood Wall Framing -- R603 Cold-formed Steel Wall Framing -- R604 Wood Structural Panels -- R605 Particleboard -- R606 General Masonry Construction -- R607 Glass Unit Masonry -- R608 Exterior Concrete Wall Construction -- R609 Exterior Windows and Doors -- R610 Structural Insulated Panel Wall Construction -- CHAPTER 7 WALL COVERING -- R701 General -- R702 Interior Covering -- R703 Exterior Covering -- R704 Soffits -- CHAPTER 8 ROOF-CEILING CONSTRUCTION -- R801 General -- R802 Wood Roof Framing -- R803 Roof Sheathing -- R804 Cold-formed Steel Roof Framing -- R805 Ceiling Finishes -- R806 Roof Ventilation -- R807 Attic Access -- CHAPTER 9 ROOF ASSEMBLIES -- R901 General -- R902 Fire Classification -- R903 Weather Protection -- R904 Materials -- R905 Requirements for Roof Coverings -- R906 Roof Insulation -- R907 Rooftop-mounted Photovoltaic Panel Systems -- R908 Reroofing -- CHAPTER 10 CHIMNEYS AND FIREPLACES -- R1001 Masonry Fireplaces -- R1002 Masonry Heaters -- R1003 Masonry Chimneys -- R1004 Factory-built Fireplaces - R1005 Factory-built Chimneys -- R1006 Exterior Air Supply -- Part IV—Energy Conservation -- CHAPTER 11 ENERGY EFFICIENCY -- N1101 General -- N1102 Building Thermal Envelope -- N1103 Systems -- N1104 Electrical Power and Lighting Systems -- N1105 Total Building Performance -- N1106 Energy Rating Index Compliance Alternative -- N1107 Tropical Climate Region Compliance Path -- N1108 Additional Efficiency Package Options -- N1109 Existing Buildings—General -- N1110 Additions -- N1111 Alterations -- N1112 Repairs -- N1113 Change of Occupancy or Use -- Part V—Mechanical -- CHAPTER 12 MECHANICAL ADMINISTRATION -- M1201 General -- M1202 Existing Mechanical Systems -- CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS -- M1301 General -- M1302 Approval -- M1303 Labeling of Appliances -- M1304 Type of Fuel -- M1305 Appliance Access -- M1306 Clearances from Combustible Construction -- M1307 Appliance Installation -- M1308 Mechanical Systems Installation -- CHAPTER 14 HEATING AND COOLING EQUIPMENT AND APPLIANCES -- M1401 General -- M1402 Central Furnaces -- M1403 Heat Pump Equipment -- M1404 Refrigeration Cooling Equipment -- M1405 Baseboard Convectors -- M1406 Radiant Heating Systems -- M1407 Duct Heaters -- M1408 Vented Floor Furnaces -- M1409 Vented Wall Furnaces -- M1410 Vented Room Heaters -- M1411 Heating and Cooling Equipment -- M1412 Absorption Cooling Equipment -- M1413 Evaporative Cooling Equipment -- M1414 Fireplace Stoves -- M1415 Masonry Heaters -- CHAPTER 15 EXHAUST SYSTEMS -- M1502 Clothes Dryer Exhaust -- M1503 Domestic Cooking Exhaust Equipment -- M1504 Exhaust Ducts and Exhaust Openings -- M1505 Mechanical Ventilation -- CHAPTER 16 DUCT SYSTEMS -- M1601 Duct Construction -- M1602 Return Air -- CHAPTER 17 COMBUSTION AIR -- M1701 General -- CHAPTER 18 CHIMNEYS AND VENTS -- M1801 General -- M1802 Vent Components -- M1803 Chimney and Vent Connectors -- M1804 Vents -- M1805 Masonry and Factory-built Chimneys -- CHAPTER 19 SPECIAL APPLIANCES, EQUIPMENT AND SYSTEMS -- M1901 Ranges and Ovens -- M1902 Sauna Heaters -- M1903 Stationary Fuel Cell Power Plants -- M1904 Gaseous Hydrogen Systems -- CHAPTER 20 BOILERS AND WATER HEATERS -- M2001 Boilers -- M2002 Operating and Safety Controls -- M2003 Expansion Tanks -- M2004 Water Heaters Used for Space Heating -- M2005 Water Heaters -- M2006 Pool Heaters -- CHAPTER 21 HYDRONIC PIPING -- M2101 Hydronic Piping Systems Installation -- M2102 Baseboard Convectors -- M2103 Floor Heating Systems -- M2104 Low Temperature Piping -- M2105 Ground-Source Heat-Pump System Loop Piping -- CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS -- M2201 Oil Tanks -- M2202 Oil Piping, Fitting and Connections -- M2203 Installation -- M2204 Oil Pumps and Valves -- CHAPTER 23 SOLAR THERMAL ENERGY SYSTEMS -- M2301 Solar Thermal Energy Systems -- Part VI—Fuel Gas -- CHAPTER 24 FUEL GAS -- G2401 General -- G2402 General -- G2403 General Definitions -- G2404 General -- G2405 Structural Safety -- G2406 Appliance Location -- G2407 Combustion, Ventilation and Dilution Air -- G2408 Installation -- G2409 Clearance Reduction -- G2410 Electrical -- G2411 Electrical Bonding -- G2412 General -- G2413 Pipe Sizing -- G2414 Piping Materials -- G2415 Piping System Installation -- G2416 Piping Bends and Changes in Direction -- G2417 Inspection, Testing and Purging -- G2418 Piping Support -- G2419 Drips and Sloped Piping -- G2420 Shutoff Valves -- G2421 Flow Controls -- G2422 Appliance Connections -- G2423 Compressed Natural Gas Motor Vehicle Fuel-dispensing Facilities -- G2424 Piping Support Intervals -- G2425 General -- G2426 Vents -- G2427 Venting of Appliances -- G2428 Sizing of Category I Appliance Venting Systems -- G2429 Direct-vent, Integral Vent, Mechanical Vent and Ventilation/Exhaust Hood Venting -- G2430 Factory-built Chimneys -- G2431 General -- G2432 Decorative Appliances for Installation in Fireplaces -- G2433 Log Lighters -- G2434 Vented Gas Fireplaces (Decorative Appliances) -- G2435 Vented Gas Fireplace Heaters -- G2436 Vented Wall Furnaces -- G2437 Floor Furnaces -- G2438 Clothes Dryers -- G2439 Clothes Dryer Exhaust -- 02440 Sauna Heaters -- G2441 Pool and Spa Heaters -- G2442 Forced-air Warm-air Furnaces -- G2443 Conversion Burners -- G2444 Unit Heaters -- G2445 Unvented Room Heaters -- G2446 Vented Room Heaters -- G2447 Cooking Appliances -- G2448 Water Heaters -- G2449 Air-conditioning Appliances -- G2450 Illuminating Appliances -- G2451 Infrared Radiant Heaters -- G2452 Boilers -- G2453 Outdoor Decorative Appliances -- Part VII—Plumbing -- CHAPTER 25 PLUMBING ADMINISTRATION -- P2501 General -- P2502 Existing Plumbing Systems -- P2503 Inspection and Tests -- CHAPTER 26 GENERAL PLUMBING REQUIREMENTS -- P2601 General -- P2602 Individual Water Supply and Sewage Disposal -- P2603 Structural and Piping Protection -- P2604 Trenching and Backfilling -- P2605 Support -- P2606 Penetrations -- P2607 Waterproofing of Openings -- P2608 Workmanship -- P2609 Materials Evaluation and Listing -- CHAPTER 27 PLUMBING FIXTURES -- P2701 Fixtures, Faucets and Fixture Fittings -- P2702 Fixture Accessories -- P2703 Tail Pieces -- P2704 Slip-joint Connections -- P2705 Installation -- P2706 Waste Receptors -- P2707 Directional Fittings -- P2708 Showers -- P2709 Shower Receptors -- P2710 Shower Walls -- P2711 Lavatories -- P2712 Water Closets -- P2713 Bathtubs -- P2714 Sinks -- P2715 Laundry Tubs -- P2716 Food-waste Disposer -- P2717 Dishwashing Machines -- P2718 Clothes Washing Machine -- P2719 Floor Drains -- P2720 Whirlpool Bathtubs -- P2721 Bidet Installations -- P2722 Fixture Fitting -- P2723 Macerating Toilet Systems -- P2724 Specialty Temperature Control Devices and Valves -- P2725 Nonliquid Saturated Treatment Systems -- CHAPTER 28 WATER HEATERS -- P2801 General -- P2802 Solar Water Heating Systems -- P2803 Water Heaters Used for Space Heating -- P2804 Relief Valves -- CHAPTER 29 WATER SUPPLY AND DISTRIBUTION -- P2901 General -- P2902 Protection of Potable Water Supply -- P2903 Water Supply System -- P2904 Dwelling Unit Fire Sprinkler Systems -- P2905 Heated Water Distribution Systems -- P2906 Materials, Joints and Connections -- P2907 Changes in Direction -- P2908 Support -- P2909 Drinking Water Treatment Units -- P2910 Nonpotable Water Systems -- P2911 On-site Nonpotable Water Reuse Systems -- P2912 Nonpotable Rainwater Collection and Distribution Systems -- P2913 Reclaimed Water Systems -- CHAPTER 30 SANITARY DRAINAGE -- P3001 General -- P3002 Materials -- P3003 Joints and Connections -- P3004 Determining Drainage Fixture Units -- P3005 Drainage System -- P3006 Sizing of Drain Pipe Offsets -- P3007 Sumps and Ejectors -- P3008 Backwater Valves -- P3009 Graywater Soil Absorption Systems -- P3010 Replacement of Underground Building Sewers and Building Drains by Pipe Bursting Methods -- P3011 Relining of Building Sewers and Building Drains -- CHAPTER 31 VENTS -- P3101 Vent Systems -- P3102 Vent Stacks and Stack Vents -- P3103 Vent Terminals -- P3104 Vent Connections and Grades -- P3105 Fixture Vents -- P3106 Individual Vent -- P3107 Common Vent -- P3108 Wet Venting -- P3109 Waste Stack Vent -- P3110 Circuit Venting -- P3111 Combination Waste and Vent System -- P3112 Island Fixture Venting -- P3113 Vent Pipe Sizing -- P3114 Air Admittance Valves -- CHAPTER 32 TRAPS -- P3201 Fixture Traps -- CHAPTER 33 STORM DRAINAGE -- P3301 General -- P3302 Subsoil Drains -- P3303 Sumps and Pumping Systems -- Part VIII—Electrical CHAPTER 34 GENERAL REQUIREMENTS -- E3401 General -- E3402 Building Structure Protection -- E3403 Inspection and Approval -- E3404 General Equipment Requirements -- E3405 Equipment Location and Clearances -- E3406 Electrical Conductors and Connections -- E3407 Conductor and Terminal Identification -- CHAPTER 35 ELECTRICAL DEFINITIONS -- E3501 General -- CHAPTER 36 SERVICES -- E3601 General Services -- E3602 Service Size and Rating -- E3603 Service, Feeder and Grounding Electrode Conductor Sizing -- E3604 Overhead Service and Service-entrance Conductor Installation -- E3605 Service-entrance Conductors -- E3606 Service Equipment—General -- E3607 System Grounding -- E3608 Grounding Electrode System -- E3609 Bonding -- E3610 Grounding Electrode Conductors -- E3611 Grounding Electrode Conductor Connection to the Grounding Electrodes -- CHAPTER 37 BRANCH CIRCUIT AND FEEDER REQUIREMENTS -- E3701 General -- E3702 Branch Circuit Ratings -- E3703 Required Branch Circuits -- E3704 Feeder Requirements -- E3705 Conductor Sizing and Overcurrent Protection -- E3706 Panelboards -- CHAPTER 38 WIRING METHODS -- E3801 General Requirements -- E3802 Above-ground Installation Requirements -- E3803 Underground Installation Requirements -- CHAPTER 39 POWER AND LIGHTING DISTRIBUTION -- E3901 Receptacle Outlets -- E3902 Ground-fault and Arc-fault Circuit-interrupter Protection -- E3903 Lighting Outlets -- E3904 General Installation Requirements -- E3905 Boxes, Conduit Bodies and Fittings -- E3906 Installation of Boxes, Conduit Bodies and Fittings -- E3907 Cabinets and Panelboards -- E3908 Grounding and Bonding -- E3909 Flexible Cords and Flexible Cables -- CHAPTER 40 DEVICES AND LUMINAIRES -- E4001 Switches -- E4002 Receptacles -- E4003 Luminaires -- E4004 Luminaire Installation -- E4005 Track Lighting -- CHAPTER 41 APPLIANCE INSTALLATION -- E4101 General -- CHAPTER 42 SWIMMING POOLS -- E4201 General -- E4202 Wiring Methods for Pools, Spas, Hot Tubs and Hydromassage Bathtubs -- E4203 Equipment Location and Clearances -- E4204 Equipotential Bonding -- E4205 Bonding and Grounding -- E4206 Equipment Installation -- E4207 Storable Swimming Pools, Storable Spas and Storable Hot Tubs -- E4208 Spas and Hot Tubs -- E4209 Hydromassage Bathtubs -- CHAPTER 43 CLASS 2 REMOTE-CONTROL SIGNALING AND POWER-LIMITED CIRCUITS -- E4301 General -- E4302 Power Sources -- E4303 Wiring Methods -- E4304 Installation Requirements -- Part IX—Referenced Standards -- CHAPTER 44 REFERENCED STANDARDS -- APPENDIX AA SIZING AND CAPACITIES OF GAS PIPING -- AA101 General Piping Considerations -- AA102 Description of Tables -- AA103 Use of Capacity Tables -- AA104 Use of Sizing Equations -- AA105 Pipe and Tube Diameters -- AA106 Examples of Piping System Design and Sizing -- APPENDIX AB SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS -- AB101 Examples Using Single-appliance Venting Tables -- AB102 Examples Using Common Venting Tables -- APPENDIX AC EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS -- AC101 General -- APPENDIX AD RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION -- AD101 General -- AD102 Occupant and Inspector Safety -- AD103 Gas Piping and Connections Inspections -- AD104 Inspections to be Performed with the Appliance Not Operating -- AD105 Inspections to be Performed with the Appliance Operating -- AD106 Appliance-specific Inspections -- APPENDIX AE MANUFACTURED HOUSING USED AS DWELLINGS -- AE101 Scope -- AE102 Application to Existing Manufactured Homes and Building Service Equipment -- AE103 Definitions -- AE104 Permits -- AE105 Application for Permit -- AE106 Permits Issuance -- AE107 Fees -- AE108 Inspections -- AE109 Special Inspections -- AE110 Utility Service -- AE111 Occupancy Classification -- AE112 Location on Property -- AE113 Design -- AE114 Foundation Systems -- AE115 Skirting and Perimeter Enclosures -- AE116 Structural Additions -- AE117 Building Service Equipment -- AE118 Exits -- AE119 Occupancy, Fire Safety and Energy Conservation Standards -- AE120 Special Requirements for Foundation Systems -- AE121 Footings and Foundations -- AE122 Pier Construction -- AE123 Height of Piers -- AE124 Anchorage Installations -- AE125 Ties, Materials and Installation -- AE126 Referenced Standards -- APPENDIX AF RADON CONTROL METHODS -- AF101 Scope -- AF102 Definitions -- AF103 Requirements -- AF104 Testing -- APPENDIX AG PIPING STANDARDS FOR VARIOUS APPLICATIONS -- AG101 Plastic Piping Standards -- AG102 Referenced Standards -- APPENDIX AH PATIO COVERS -- AH101 General -- AH102 Definition -- AH103 Exterior Walls and Openings -- AH104 Height -- AH105 Structural Provisions -- AH106 Special Provisions for Aluminum Screen Enclosures in Hurricane-prone Regions -- APPENDIX AI PRIVATE SEWAGE DISPOSAL -- AI101 General -- APPENDIX AJ EXISTING BUILDINGS AND STRUCTURES -- AJ101 Purpose and Intent -- AJ102 Compliance -- AJ103 Preliminary Meeting -- AJ104 Evaluation of an Existing Building -- AJ105 Permit -- AJ106 Definitions -- AJ107 Repairs -- AJ108 Renovations -- AJ109 Alterations -- AJ110 Reconstruction -- AJ111 Referenced Standards -- APPENDIX AK SOUND TRANSMISSION -- AK101 General -- AK102 Airborne Sound -- AK103 Structural-borne Sound -- AK104 Referenced Standards -- APPENDIX AL PERMIT FEES -- AL101 General -- APPENDIX AM HOME DAY CARE—R-3 OCCUPANCY -- AM101 General -- AM102 Definition -- AM103 Means of Egress -- AM104 Smoke Detection -- APPENDIX AN VENTING METHODS -- AN101 Venting Methods -- APPENDIX AO AUTOMATIC VEHICULAR GATES -- AO101 General -- AO102 Definition -- AO103 Automatic Vehicular Gates -- AO104 Referenced Standards -- APPENDIX AP SIZING OF WATER PIPING SYSTEM -- AP101 General -- AP102 Information Required -- AP103 Selection of Pipe Size -- AP201 Selection of Pipe Size -- APPENDIX AQ TINY HOUSES -- AQ101 General -- AQ102 Definitions -- AQ103 Ceiling Height -- AQ104 Lofts -- AQ105 Emergency Escape and Rescue Openings -- AQ106 Energy Conservation -- APPENDIX AR LIGHT STRAW-CLAY CONSTRUCTION -- AR101 General -- AR102 Definitions -- AR103 Nonbearing Light Straw-Clay Construction -- AR104 Thermal Performance -- AR105 Referenced Standards -- APPENDIX AS STRAWBALE CONSTRUCTION -- AS101 General -- AS102 Definitions -- AS103 Bales -- AS104 Finishes -- AS105 Strawbale Walls—General -- AS106 Strawbale Walls—Structural -- AS107 Fire Resistance -- AS108 Thermal Insulation -- AS109 Referenced Standards -- APPENDIX AT SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES -- AT101 Scope -- AT102 General Definition -- AT103 Solar-ready Zone -- APPENDIX AU COB CONSTRUCTION (MONOLITHIC ADOBE) -- AU101 General -- AU102 Definitions -- AU103 Materials, Mixing and Installation -- AU104 Finishes -- AU105 Cob Walls—General -- AU106 Cob Walls—Structural -- AU107 Cob Floors -- AU108 Fire Resistance -- AU109 Thermal Performance -- AU110 Referenced Standards -- APPENDIX AV BOARD OF APPEALS -- AV101 General -- APPENDIX AW 3D-PRINTED BUILDING CONSTRUCTION -- AW101 General -- AW102 Definitions -- AW103 Building Design -- AW104 Building Construction -- AW105 Special Inspections -- AW106 Referenced Standards -- INDEX -- RESOURCE A RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS (RVI).
650 0 _aHouse construction
_xStandards.
_9112574
_2Local
650 0 _aBulding laws.
_9205681
_2Local
650 0 0 _aHousing
_xLaw and legislation.
_9112622
_2Local
942 _2lcc
_c37
_eJanuary 29, 2021
_hKF5701.A73
_mI58 2021
_kReferencia
999 _c296072
_d296072