Significant changes to the International Building Code. / Douglas W. Thornburg, AIA, CBO ; Sandra Hyde, P.E. ; Jay Woodward txt

Por: Colaborador(es): Series The International CodesWashington, D.C. : International Code Council, 2021Edición: 2021 EditionDescripción: 410 pages : ill. ; col. ;photo ; 28 cmTipo de contenido:
  • text
Tipo de medio:
  • unmediaded
Tipo de soporte:
  • volume
ISBN:
  • 9781952468186
Tema(s): Clasificación LoC:
  • KF5701 I524 2021
Contenidos:
Part 1 Administration Chapters 1 and 2 -- Chapter 1 Format of Administrative Provisions -- 110.3.5 Type IV Connection Protection -- 110.3.7 Inspection of Weather-Exposed Balconies -- 202 Definition of Atrium -- 202 Definition of Change of Occupancy -- 202 Definition of Impact Protective System -- 202 Definition of Mass Timber -- 202 Definition of Nailable Substrate -- 202 Definition of Penthouse -- 202 Definition of Puzzle Room -- 202 Definition of Structural Members -- PART 2 Building Planning -- Chapters 3 through 6 -- 306.2 Group F-1 Occupancy Classification -- 307.1.1 Uses Not Classified as Group H -- 311.2, 311.3 Alcoholic Beverage Storage -- 403.3.2 Water Supply to Required Fire Pumps -- 404.1 Scope of Atrium Provisions -- 404.5 Smoke Control in Atriums -- 404.6 Horizontal Assemblies in Atriums -- 406.2.4 Floor Surfaces in Parking Garages -- 407.3.1.1 Group 1-2 Corridor Doors -- 407.4.4.1, 407.4.4.3 Group 1-2 Care Suites -- 407.6.1 Automatic-Closing Doors in Group 1-2 -- 411.5 Puzzle Rooms -- 414.2.3 Fire Wall Use for Control Areas -- 422.7 Cooking in Ambulatory Care Facilities -- 424 Play Structures -- 503.1.4 Occupied Roof Allowances -- Table 504.3 Allowable Height in Feet -- Table 504.4 Allowable Height in Stories -- Table 506.2 Allowable Building Area -- 506.3.2 Allowable Area Frontage Increase -- 508.4.4 Separated Occupancies -- 508.4.4.1, 509.4.1.1 Fire Separations of Mass Timber -- 508.5 Live/Work Units -- Table 509.1 Storage Battery Systems as Incidental Uses -- 510.2 Stairway Construction in Podium Buildings -- Table 601 Type IV Fire-Resistance -- 602.4 Mass Timber Type IV Buildings -- 602.4.1-602.4.3 Type IV-A, IV-B and IV-C Buildings -- 602.4.4 Type IV-HT Buildings -- 603.1 Combustible Materials in Types I and II -- PART 3 Fire Protection -- Chapters 7 through 9 -- 703.6, 703.7 Noncombustible Protection for Mass Timber -- 704.6.1 Secondary Attachments and Fireproofing -- Table 705.5 Exterior Wall Ratings -- 707.4, 716 Separations of Energy Storage Systems -- 707.5 Enclosure of Exit Passageways -- 708.1, 708.4.1 Supporting Construction for Fire Partitions -- 709.4.1 Smoke Barrier Continuity -- 710.5.2.1, 710.5.3 Smoke Partition Openings -- 713.12 Top of Shaft Enclosure -- 715 Protection of Joints and Voids -- 716.2.2.1.1 Prohibited Use of Terminated Stops -- 716.4 Fire-Protective Curtain Assemblies -- Table 716.1(2) Doors in Double Fire Walls -- 717.2.3, 717.6.2.1 Ceiling Radiation Dampers -- 717.4 Access to Dampers -- 717.5.2 Flex Connectors -- 722.7 Fire-Resistance Rating of Mass Timber -- 806.9 Combustible Lockers as Interior Finish -- 903.2.4. 903.2.7, 903.2.9 Upholstered Furniture and Mattresses -- 903.2.4.2, 903.2.9.3 Distilled Spirits -- 903.2.10 Sprinklers in Parking Garages -- 903.2.10.2 Mechanical-Access Parking Garages -- 903.3.1.2 NFPA 13R Sprinkler Protection -- 903.3.1.2.2 Corridor and Balcony Sprinklers -- 905.3.1 Standpipes in Parking Garages -- 907.2.10 Manual Alarms in Group S Buildings -- 907.5.2.1.3 Fire Alarm Occupant Notification -- 909.20 Smokeproof Enclosures -- 911 Fire Command Centers in Groups F-1 and S-1 -- PART 4 Means of Egress Chapter 10 -- 1006.2.1 Egress from Mechanical Rooms and Penthouses -- 1006.3 Egress from Occupied Roofs -- 1006.3.4 Single Exit Stories -- 1008.2.1 Stairway Illumination -- 1009.2.1 Accessible Elevators to Occupied Roofs -- 1009.6.2 Areas of Refuge -- 1009.6.3, 3008.6.4 Area of Refuge Floor Space -- 1010.1.1 Door Widths -- 1010.1.1.1 Projections into Door Openings -- 1010.1.3 Door Opening Forces -- 1010.2.4 Locks and Latches -- 1010.2.8 Locking Arrangements in Group 1-4 -- 1011.6 Stairway Landings -- 1016.2 Egress Through Intervening Spaces -- 1019.3 Exit Access Stairways -- 1020.5 Dead-End Corridors -- 1030.16 Handrails at Social Stairs -- 1031 Emergency Escape and Rescue Openings -- PART 5 Accessibility -- Chapter 11 -- 1102 Accessible Design Compliance -- 1104.4 Accessible Multistory Buildings -- 1105.1.1 Automatic Doors at Public Entrances -- 1107.2 Vehicle Charging Stations -- 1108.5, 1110.2 Assisted Toileting and Bathing -- 1110.6 Bottle Filling Stations -- 1110.13.2 Service Windows -- 1110.15 Operable Parts -- PART 6 Building Envelope, Structural Systems, and Construction Materials -- Chapters 12 through 26 -- 1202.3 Insulation of Unvented Attics -- 1207 Enhanced Classroom Acoustics -- 1208.4 Efficiency Dwelling Units -- 1210.3 Restroom Privacy -- 1404.3 Vapor Retarders -- Table 1404.3.1 Class II Vapor Retarders -- 1404.3.2 Class III Vapor Retarders -- 1406.10 Metal Composite Material Cladding -- 1503.3 Parapet Walls -- 1504.5 Ballasted Roofs -- 1504.9 Aggregate-Surfaced Roofs -- 1603.1.4 Construction Document Wind Zones -- Table 1604.5 Risk Categories of Assembly Spaces -- 1605 Load Combinations -- 1606 Dead Loads -- 1607.11.4 Rope Descent Systems -- 1607.17 Fixed Ladder Live Load -- 1608.2 Snow Maps -- 1610.2 Soil-Caused Uplift -- 1611 Rain Loads -- 1612.4 Flood Hazard Documents -- 1704.6 Structural Observations -- Table 1705.3 Special Inspection of Precast Concrete -- 1705.4.1 Empirically Designed Masonry -- 1705.5.3, 1705.20 Mass Timber Special Inspection -- 1705.10 Structural Integrity of Deep Foundations -- 1705.13.7 Special Inspection of Storage Racks -- 1705.18 Firestop Inspections in Group R -- 1709.5 Window and Door Assemblies -- 1709.5.3 Impact Protection -- 1809.5.1 Frost Protection at Required Exits -- Table 1810.3.2.6 Allowable Stresses in Deep Foundations -- 1810.3.3.1.9 Helical Piles -- 1810.3.5.3.1 Structural Steel H-piles -- 1810.3.6 Deep Foundation Element Splicing -- 1810.3.8 Precast Concrete Piles -- 1810.3.11 Pile Caps -- 1810.4.5 Vibratory Drivers -- 1901.2 Concrete Design and Construction -- 1901.7 Structural Concrete Tolerances -- 2109.2.4.8 Exterior Finish of Adobe Masonry -- 2205.2.1 AISC 358 for Prequalified Connections -- 2209 Steel Storage Racks -- 2303.2 Fire-Retardant-Treated Wood -- 2303.4.1.2 Wood Truss Bracing -- 2304.10.1 Mass Timber Connection Protection -- Table 2304.10.2 Sheathing Fasteners -- 2304.11 Concealed Spaces in Type IV-HT -- 2305 Lateral Force-Resisting Systems -- 2308.5.6, 2308.6.6.2 Cripple Walls -- Table 2308.7.3.1 Rafter Tie Connections -- 2510.6 Water-Resistive Barriers for Stucco -- PART 7 Building Services, Special Devices, and Special Conditions -- Chapters 27 through 33 -- 2902 Minimum Plumbing Facilities -- 2902.3.3 Toilet Fixtures in Storage Facilities -- 3001.2 Emergency Elevator Communication Systems -- 3103.1 Special Event Structures -- 3114 Public Use Restrooms in Flood Hazard Areas -- 3115 Intermodal Shipping Containers -- 3313 Fire Protection During Construction -- PART 8 Appendices Appendices A through 0 -- Appendix B Board of Appeals -- Appendix O Application of ICC Performance Code -- PART 9 2021 International Existing Building Code (IEBC) -- Chapters 1 through 16 and Appendices A through C -- 303 Storm Shelters -- 306.7 Accessible Toilet and Bathing Rooms -- 307, 308 Smoke Alarms and CO Detection -- 309 Exterior Wall Coverings and Envelopes - 405.2.4 Snow Loads and Substantial Damag-e 502.6, 503.16, 506.6 Classroom Acoustics -- 503.4 Rooftop Equipment Dead Load -- 503.12, 706.3.2 Roof Diaphragm Wind Loads -- 503.17, 704.3 Locking in Educational Occupancies -- 506.4, 1011.5.1, 1011.5.6 Emergency Escape and Rescue Openings -- 506.5.3, 1006.3 Change of Occupancy from Group S or U -- 603.1, 704, 801.3 Furniture and Equipment -- 704.1.1 Seating in Nursing Home Corridors -- 803.2.2, 803.2.3, 803.2.5 Sprinklers and Level 2 Alterations -- 904.1.4, 904.1.5, 904.1.6, 904.1.7 Sprinklers and Level 3 Alterations -- 1002.1, 1002.2 Special Uses and Incidental Uses -- 1011.1, 1011.2 Change of Occupancy Applicability --
Valoración
    Valoración media: 0.0 (0 votos)
Existencias
Imagen de cubierta Tipo de ítem Biblioteca actual Biblioteca de origen Colección Ubicación en estantería Signatura topográfica Materiales especificados Info Vol URL Copia número Estado Notas Fecha de vencimiento Código de barras Reserva de ítems Prioridad de la cola de reserva de ejemplar Reservas para cursos
Libro Referencia CARIBET CARIBET Biblioteca Arquitectura Colección de Referencia CARIBET Referencia KF5701 I524 2021 (Navegar estantería(Abre debajo)) 1 Disponible 91000000064808
Total de reservas: 0

Descripciones mejoradas de Syndetics:

Gain full access to over 155 of the most significant changes to the International Building Code, including the real-world application of those changes and how they originated -- all in a single, easy-to-use resource. SIGNIFICANT CHANGES TO THE INTERNATIONAL BUILDING CODE 2021 Edition provides a comprehensive analysis of significant changes since the 2018 IBC , offering key insights into its contents and implications. Coverage includes changes made to both structural and non-structural provisions. Each change analysis features the affected code sections and identifies the change with strikethroughs and underlines to show modifications to the existing language. Each change is accompanied by a quick summary, detailed illustrations, and discussion of its significance, which brings the technical jargon of the code to life in a real-world setting. The attention to detail, logical organization, and thorough yet concise coverage found in this resource make it an ideal tool for transitioning from the 2018 IBC.

Part 1 Administration Chapters 1 and 2 --
Chapter 1 Format of Administrative Provisions --
110.3.5 Type IV Connection Protection --
110.3.7 Inspection of Weather-Exposed Balconies --
202 Definition of Atrium --
202 Definition of Change of Occupancy --
202 Definition of Impact Protective System --
202 Definition of Mass Timber --
202 Definition of Nailable Substrate --
202 Definition of Penthouse --
202 Definition of Puzzle Room --
202 Definition of Structural Members --
PART 2 Building Planning --
Chapters 3 through 6 --
306.2 Group F-1 Occupancy Classification --
307.1.1 Uses Not Classified as Group H --
311.2, 311.3 Alcoholic Beverage Storage --
403.3.2 Water Supply to Required Fire Pumps --
404.1 Scope of Atrium Provisions --
404.5 Smoke Control in Atriums --
404.6 Horizontal Assemblies in Atriums --
406.2.4 Floor Surfaces in Parking Garages --
407.3.1.1 Group 1-2 Corridor Doors --
407.4.4.1, 407.4.4.3 Group 1-2 Care Suites --
407.6.1 Automatic-Closing Doors in Group 1-2 --
411.5 Puzzle Rooms --
414.2.3 Fire Wall Use for Control Areas --
422.7 Cooking in Ambulatory Care Facilities --
424 Play Structures --
503.1.4 Occupied Roof Allowances --
Table 504.3 Allowable Height in Feet --
Table 504.4 Allowable Height in Stories --
Table 506.2 Allowable Building Area --
506.3.2 Allowable Area Frontage Increase --
508.4.4 Separated Occupancies --
508.4.4.1, 509.4.1.1 Fire Separations of Mass Timber --
508.5 Live/Work Units --
Table 509.1 Storage Battery Systems as Incidental Uses --
510.2 Stairway Construction in Podium Buildings --
Table 601 Type IV Fire-Resistance --
602.4 Mass Timber Type IV Buildings --
602.4.1-602.4.3 Type IV-A, IV-B and IV-C Buildings --
602.4.4 Type IV-HT Buildings --
603.1 Combustible Materials in Types I and II --
PART 3 Fire Protection --
Chapters 7 through 9 --
703.6, 703.7 Noncombustible Protection for Mass Timber --
704.6.1 Secondary Attachments and Fireproofing --
Table 705.5 Exterior Wall Ratings --
707.4, 716 Separations of Energy Storage Systems --
707.5 Enclosure of Exit Passageways --
708.1, 708.4.1 Supporting Construction for Fire Partitions --
709.4.1 Smoke Barrier Continuity --
710.5.2.1, 710.5.3 Smoke Partition Openings --
713.12 Top of Shaft Enclosure --
715 Protection of Joints and Voids --
716.2.2.1.1 Prohibited Use of Terminated Stops --
716.4 Fire-Protective Curtain Assemblies --
Table 716.1(2) Doors in Double Fire Walls --
717.2.3, 717.6.2.1 Ceiling Radiation Dampers --
717.4 Access to Dampers --
717.5.2 Flex Connectors --
722.7 Fire-Resistance Rating of Mass Timber --
806.9 Combustible Lockers as Interior Finish --
903.2.4. 903.2.7, 903.2.9 Upholstered Furniture and Mattresses --
903.2.4.2, 903.2.9.3 Distilled Spirits --
903.2.10 Sprinklers in Parking Garages --
903.2.10.2 Mechanical-Access Parking Garages --
903.3.1.2 NFPA 13R Sprinkler Protection --
903.3.1.2.2 Corridor and Balcony Sprinklers --
905.3.1 Standpipes in Parking Garages --
907.2.10 Manual Alarms in Group S Buildings --
907.5.2.1.3 Fire Alarm Occupant Notification --
909.20 Smokeproof Enclosures --
911 Fire Command Centers in Groups F-1 and S-1 --
PART 4 Means of Egress Chapter 10 --
1006.2.1 Egress from Mechanical Rooms and Penthouses --
1006.3 Egress from Occupied Roofs --
1006.3.4 Single Exit Stories --
1008.2.1 Stairway Illumination --
1009.2.1 Accessible Elevators to Occupied Roofs --
1009.6.2 Areas of Refuge --
1009.6.3, 3008.6.4 Area of Refuge Floor Space --
1010.1.1 Door Widths --
1010.1.1.1 Projections into Door Openings --
1010.1.3 Door Opening Forces --
1010.2.4 Locks and Latches --
1010.2.8 Locking Arrangements in Group 1-4 --
1011.6 Stairway Landings --
1016.2 Egress Through Intervening Spaces --
1019.3 Exit Access Stairways --
1020.5 Dead-End Corridors --
1030.16 Handrails at Social Stairs --
1031 Emergency Escape and Rescue Openings --
PART 5 Accessibility --
Chapter 11 --
1102 Accessible Design Compliance --
1104.4 Accessible Multistory Buildings --
1105.1.1 Automatic Doors at Public Entrances --
1107.2 Vehicle Charging Stations --
1108.5, 1110.2 Assisted Toileting and Bathing --
1110.6 Bottle Filling Stations --
1110.13.2 Service Windows --
1110.15 Operable Parts --
PART 6 Building Envelope, Structural Systems, and Construction Materials --
Chapters 12 through 26 --
1202.3 Insulation of Unvented Attics --
1207 Enhanced Classroom Acoustics --
1208.4 Efficiency Dwelling Units --
1210.3 Restroom Privacy --
1404.3 Vapor Retarders --
Table 1404.3.1 Class II Vapor Retarders --
1404.3.2 Class III Vapor Retarders --
1406.10 Metal Composite Material Cladding --
1503.3 Parapet Walls --
1504.5 Ballasted Roofs --
1504.9 Aggregate-Surfaced Roofs --
1603.1.4 Construction Document Wind Zones --
Table 1604.5 Risk Categories of Assembly Spaces --
1605 Load Combinations --
1606 Dead Loads --
1607.11.4 Rope Descent Systems --
1607.17 Fixed Ladder Live Load --
1608.2 Snow Maps --
1610.2 Soil-Caused Uplift --
1611 Rain Loads --
1612.4 Flood Hazard Documents --
1704.6 Structural Observations --
Table 1705.3 Special Inspection of Precast Concrete --
1705.4.1 Empirically Designed Masonry --
1705.5.3, 1705.20 Mass Timber Special Inspection --
1705.10 Structural Integrity of Deep Foundations --
1705.13.7 Special Inspection of Storage Racks --
1705.18 Firestop Inspections in Group R --
1709.5 Window and Door Assemblies --
1709.5.3 Impact Protection --
1809.5.1 Frost Protection at Required Exits --
Table 1810.3.2.6 Allowable Stresses in Deep Foundations --
1810.3.3.1.9 Helical Piles --
1810.3.5.3.1 Structural Steel H-piles --
1810.3.6 Deep Foundation Element Splicing --
1810.3.8 Precast Concrete Piles --
1810.3.11 Pile Caps --
1810.4.5 Vibratory Drivers --
1901.2 Concrete Design and Construction --
1901.7 Structural Concrete Tolerances --
2109.2.4.8 Exterior Finish of Adobe Masonry --
2205.2.1 AISC 358 for Prequalified Connections --
2209 Steel Storage Racks --
2303.2 Fire-Retardant-Treated Wood --
2303.4.1.2 Wood Truss Bracing --
2304.10.1 Mass Timber Connection Protection --
Table 2304.10.2 Sheathing Fasteners --
2304.11 Concealed Spaces in Type IV-HT --
2305 Lateral Force-Resisting Systems --
2308.5.6, 2308.6.6.2 Cripple Walls --
Table 2308.7.3.1 Rafter Tie Connections --
2510.6 Water-Resistive Barriers for Stucco --
PART 7 Building Services, Special Devices, and Special Conditions --
Chapters 27 through 33 --
2902 Minimum Plumbing Facilities --
2902.3.3 Toilet Fixtures in Storage Facilities --
3001.2 Emergency Elevator Communication Systems --
3103.1 Special Event Structures --
3114 Public Use Restrooms in Flood Hazard Areas --
3115 Intermodal Shipping Containers --
3313 Fire Protection During Construction --
PART 8 Appendices Appendices A through 0 --
Appendix B Board of Appeals --
Appendix O Application of ICC Performance Code --
PART 9 2021 International Existing Building Code (IEBC) --
Chapters 1 through 16 and Appendices A through C --
303 Storm Shelters --
306.7 Accessible Toilet and Bathing Rooms --
307, 308 Smoke Alarms and CO Detection --
309 Exterior Wall Coverings and Envelopes -
405.2.4 Snow Loads and Substantial Damag-e
502.6, 503.16, 506.6 Classroom Acoustics --
503.4 Rooftop Equipment Dead Load --
503.12, 706.3.2 Roof Diaphragm Wind Loads --
503.17, 704.3 Locking in Educational Occupancies --
506.4, 1011.5.1, 1011.5.6 Emergency Escape and Rescue Openings --
506.5.3, 1006.3 Change of Occupancy from Group S or U --
603.1, 704, 801.3 Furniture and Equipment --
704.1.1 Seating in Nursing Home Corridors --
803.2.2, 803.2.3, 803.2.5 Sprinklers and Level 2 Alterations --
904.1.4, 904.1.5, 904.1.6, 904.1.7 Sprinklers and Level 3 Alterations --
1002.1, 1002.2 Special Uses and Incidental Uses --
1011.1, 1011.2 Change of Occupancy Applicability --

Tabla de contenidos provista por Syndetics

  • Part 1 Administration Chapters 1 and 2(p. 1)
  • Chapter 1 Format of Administrative Provisions(p. 2)
  • 110.3.5 Type IV Connection Protection(p. 5)
  • 110.3.7 Inspection of Weather-Exposed Balconies(p. 7)
  • 202 Definition of Atrium(p. 9)
  • 202 Definition of Change of Occupancy(p. 11)
  • 202 Definition of Impact Protective System(p. 13)
  • 202 Definition of Mass Timber(p. 15)
  • 202 Definition of Nailable Substrate(p. 17)
  • 202 Definition of Penthouse(p. 18)
  • 202 Definition of Puzzle Room(p. 20)
  • 202 Definition of Structural Members(p. 22)
  • Part 2 Building Planning Chapters 3 through 6(p. 24)
  • 306.2 Group F-l Occupancy Classification(p. 26)
  • 307.1.1 Uses Not Classified as Group H(p. 28)
  • 311.2, 311.3 Alcoholic Beverage Storage(p. 30)
  • 403.3.2 Water Supply to Required Fire Pumps(p. 32)
  • 404.1 Scope of Atrium Provisions(p. 34)
  • 404.5 Smoke Control in Atriums(p. 36)
  • 404.6 Horizontal Assemblies in Atriums(p. 38)
  • 406.2.4 Floor Surfaces in Parking Garages(p. 40)
  • 407.3.1.1 Group 1-2 Corridor Doors(p. 42)
  • 407.4.4.1, 407.4.4.3 Group 1-2 Care Suites(p. 44)
  • 407.6.1 Automatic-Closing Doors in Group 1-2(p. 46)
  • 411.5 Puzzle Rooms(p. 48)
  • 414.2.3 Fire Wall Use for Control Areas(p. 50)
  • 422.7 Cooking in Ambulatory Care Facilities(p. 52)
  • 424 Play Structures(p. 54)
  • 503.1.4 Occupied Roof Allowances(p. 56)
  • Table 504.3 Allowable Height in Feet(p. 58)
  • Table 504.4 Allowable Height in Stories(p. 60)
  • Table 506.2 Allowable Building Area(p. 63)
  • 506.3.2 Allowable Area Frontage Increase(p. 67)
  • 508.4.4 Separated Occupancies(p. 71)
  • 508.4.4.1, 509.4.1.1 Fire Separations of Mass Timber(p. 72)
  • 508.5 Live/Work Units(p. 74)
  • Table 509.1 Storage Battery Systems as Incidental Uses(p. 76)
  • 510.2 Stairway Construction in Podium Buildings(p. 78)
  • Table 601 Type IV Fire-Resistance(p. 80)
  • 602.4 Mass Timber Typo IV Buildings(p. 82)
  • 602.4.1-602.4.3 Type IV-A, IV-B and IV-C Buildings(p. 85)
  • 602.4.4 Type IV-HT Buildings(p. 91)
  • 603.1 Combustible Materials in Types I and II(p. 94)
  • Part 3 Fire Protection Chapters 7 through 9(p. 96)
  • 703.6, 703.7 Noncombustible Protection for Mass Timber(p. 98)
  • 704.6.1 Secondary Attachments and Fireproofing(p. 101)
  • Table 703.5 Exterior Wall Ratings(p. 103)
  • 707.4, 716 Separations of Energy Storage Systems(p. 105)
  • 707.5 Enclosure of Exit Passageways(p. 109)
  • 708.1.708.4.1 Supporting Construction for Fire Partitions(p. 111)
  • 709.4.1 Smoke Barrier Continuity(p. 113)
  • 710.5.2.1, 710.5.3 Smoke Partition Openings(p. 115)
  • 713.12 Top of Shaft Enclosure(p. 117)
  • 715 Protection of Joints and Voids(p. 119)
  • 716.2.2.1.1 Prohibited Use of Terminated Stops(p. 122)
  • 716.4 Fire-Protective Curtain Assemblies(p. 124)
  • Table 716.1(2) Doors in Double Fire Walls(p. 126)
  • 717.2.3, 717.6.2.1 Coiling Radiation Dampers(p. 129)
  • 717.4 Access to Dampers(p. 132)
  • 717.5.2 Flex Connectors(p. 134)
  • 722.7 Fire-Resistance Rating of Mass Timber(p. 136)
  • 806.9 Combustible Lockers as Interior Finish(p. 140)
  • 903.2.4, 903.2.7, 903.2.9 Upholstered Furniture and Mattresses(p. 142)
  • 903.2.4.2, 903.2.9.3 Distilled Spirits(p. 145)
  • 903.2.10 Sprinklers in Parking Garages(p. 146)
  • 903.2.10.2 Mechanical-Access Parking Garages(p. 148)
  • 903.3.1.2 NFPA 13R Sprinkler Protection(p. 150)
  • 903.3.1.2.2 Corridor and Balcony Sprinklers(p. 152)
  • 905.3.1 Standpipes in Parking Garages(p. 154)
  • 907.2.10 Manual Alarms in Group S Buildings(p. 156)
  • 907.5.2.1.3 Fire Alarm Occupant Notification(p. 158)
  • 909.20 Smokeproof Enclosures(p. 161)
  • 911 Fire Command Centers in Groups P-l and S-l(p. 164)
  • Part 4 Means of Egress Chapter 10(p. 166)
  • 1006.2.1 Egress from Mechanical Rooms and Penthouses(p. 168)
  • 1006.3 Egress from Occupied Roofs(p. 170)
  • 1006.3.4 Single Exit Stories(p. 172)
  • 1008.2.1 Stairway Illumination(p. 175)
  • 1009.2.1 Accessible Elevators to Occupied Roofs(p. 177)
  • 1009.6.2 Areas of Refuge(p. 179)
  • 1009.6.3.3008.6.4 Area of Refuge Floor Space(p. 181)
  • 1010.1.1 Door Widths(p. 183)
  • 1010.1.1.1 Projections into Door Openings(p. 186)
  • 1010.1.3 Door Opening Forces(p. 187)
  • 1010.2.4 Locks and Latches(p. 189)
  • 1010.2.8 Locking Arrangements in Group 1-4(p. 192)
  • 1011.6 Stairway Landings(p. 194)
  • 1016.2 Egress Through Intervening Spaces(p. 196)
  • 1019.3 Exit Access Stairways(p. 197)
  • 1020.5 Dead-End Corridors(p. 199)
  • 1030.16 Handrails at Social Stairs(p. 201)
  • 1031 Emergency Escape and Rescue Openings(p. 203)
  • Part 5 Accessibility Chapter 11(p. 208)
  • 1102 Accessible Design Compliance(p. 209)
  • 1104.4 Accessible Multistory Buildings(p. 211)
  • 1105.1.1 Automatic Doors al Public Entrances(p. 213)
  • 1107.2 Vehicle Charging Stations(p. 216)
  • 1108.5, 1110.2 Assisted Toileting and Bathing(p. 218)
  • 1110.6 Bottle Filling Stations(p. 224)
  • 1110.13.2 Service Windows(p. 225)
  • 1110.15 Operable Parts(p. 227)
  • Part 6 Building Envelope, Structural Systems, and Construction Materials Chapters 12 through 26(p. 229)
  • 1202.3 Insulation of Unvented Allies(p. 232)
  • 1207 Enhanced Classroom Acoustics(p. 234)
  • 1208.4 Efficiency Dwelling Units(p. 236)
  • 1210.3 Restroom Privacy(p. 238)
  • 1404.3 Vapor Retarders(p. 239)
  • Table 1404.3.1 Class II Vapor Retarders(p. 241)
  • 1404.3.2 Class ID Vapor Retarders(p. 243)
  • 1406.10 Metal Composite Material Cladding(p. 246)
  • 1503.3 Parapet Walls(p. 248)
  • 1504.5 Ballasted Roofs(p. 250)
  • 1504.9 Aggregate-Surfaced Roofs(p. 252)
  • 1603.1.4 Construction Document Wind Zones(p. 254)
  • Table 1604.5 Risk Categories of Assembly Spaces(p. 258)
  • 1605 Load Combinations(p. 261)
  • 1606 Dead Loads(p. 264)
  • 1607.11.4 Rope Descent Systems(p. 266)
  • 1607.17 Fixed Ladder Live Load(p. 267)
  • 1608.2 Snow Maps(p. 268)
  • 1610.2 Soil-Caused Uplift(p. 270)
  • 1611 Rain Loads(p. 272)
  • 1612.4 Flood Hazard Documents(p. 278)
  • 1704.6 Structural Observations(p. 280)
  • Table 1705.3 Special Inspection of Precast Concrete(p. 283)
  • 1705.4.1 Empirically Designed Masonry(p. 285)
  • 1705.5.3, 1705.20 Mass Timber Special Inspection(p. 286)
  • 1705.10 Structural Integrity of Deep Foundations(p. 289)
  • 1705.13.7 Special Inspection of Storage Racks(p. 291)
  • 1705.18 Firestop Inspections in Group R(p. 292)
  • 1709.5 Window and Door Assemblies(p. 293)
  • 1709.5.3 Impact Protection(p. 295)
  • 1809.5.1 Frost Protection al Required Exits(p. 297)
  • Table 1810.3.2.6 Allowable Stresses in Deep Foundations(p. 298)
  • 1810.3.3.1.9 Helical Piles(p. 301)
  • 1810.3.5.3.1 Structural Steel H-piles(p. 303)
  • 1810.3.6 Deep Foundation Element Splicing(p. 305)
  • 1810.3.8 Precast Concrete Piles(p. 307)
  • 1810.3.11 Pile Caps(p. 309)
  • 1810.4.5 Vibratory Drivers(p. 311)
  • 1901.2 Concrete Design and Construction(p. 313)
  • 1901.7 Structural Concrete Tolerances(p. 315)
  • 2109.2.4.6 Exterior Finish of Adobe Masonry(p. 317)
  • 2205.2.1 AISC 358 tor Prequalified Connections(p. 320)
  • 2209 Steel Storage Racks(p. 323)
  • 2303.2 Fire-Retardant-Treated Wood(p. 325)
  • 2303.4.1.2 Wood Truss Bracing(p. 327)
  • 2304.10.1 Mass Timber Connection Protection(p. 330)
  • Table 2304.10.2 Sheathing Fasteners(p. 335)
  • 2304.11 Concealed Spaces in Type IV-HT(p. 337)
  • 2305 Lateral Force-Resisting Systems(p. 338)
  • 2308.5.6, 2308.6.6.2 Cripple Walls(p. 340)
  • Table 2308.7.3.1 Rafter Tic Connections(p. 342)
  • 2510.6 Water-Resistive Barriers for Stucco(p. 345)
  • Part 7 Building Services, Special Devices, and Special Conditions Chapters 27 through 33(p. 347)
  • 2902 Minimum Plumbing Facilities(p. 348)
  • 2902.3.3 Toilet Fixtures in Storage Facilities(p. 351)
  • 3001.2 Emergency Elevator Communication Systems(p. 353)
  • 3103.1 Emergency Elevator Communication Systems(p. 353)
  • 3114 Public Use Restrooms in Flood Hazard Areas(p. 357)
  • 3115 Intermodal Shipping Containers(p. 360)
  • 3313 Fire Protection During Construction(p. 363)
  • Part 8 Appendices Appendices A through O(p. 366)
  • Appendix B Board of Appeals(p. 367)
  • Appendix Application of ICC Performance Code(p. 371)
  • Part 9 2021 International Existing Building Code (IEBC) Chapters 1 through 16 and Appendices A through C(p. 375)
  • 303 Storm Shelters(p. 377)
  • 306.7 Accessible Toilet and Bathing Rooms(p. 380)
  • 307, 308 Smoke Alarms and CO Detection(p. 382)
  • 309 Exterior Wall Coverings and Envelopes(p. 384)
  • 465.2.4 Snow Loads and Substantial Damage(p. 386)
  • 502.6, 503.10, 506.6 Classroom Acoustics(p. 387)
  • 503.4 Rooftop Equipment Dead Load(p. 389)
  • 503.12, 706.3.2 Roof Diaphragm Wind Loads(p. 391)
  • 503.17, 704.3 Locking in Educational Occupancies(p. 393)
  • 506.4, 1011.5.1, 1011.5.6 Emergency Escape and Rescue Openings(p. 395)
  • 506.5.3, 1006.3 Change of Occupancy from Group S or U(p. 398)
  • 603.1, 704, 801.3 Furniture and Equipment(p. 400)
  • 704.1.1 Seating in Nursing Home Corridors(p. 402)
  • 803.2.2, 803.2.3, 803.2.5 Sprinklers and Level 2 Alterations(p. 403)
  • 904.1.4, 904.1.5, 904.1.6, 904.1.7 Sprinklers and Level 3 Alterations(p. 405)
  • 1002.1, 1002.2 Special Uses and Incidental Uses(p. 407)
  • 1011.1, 1011.2 Change of Occupancy Applicability(p. 409)
Compartir
logopucpr-y-vive

Contáctanos

¡Queremos saber de ti!

Tel. 787.841.2000 Ext. 1801

bibliotecavaldes@pucpr.edu

⁣Búscanos en las redes

© 2026 Desarrollado por Ignite Online • All Rights Reserved • Powered by Koha.