TY - BOOK AU - Thornburg, Douglas W. AU - Hyde, Sandra AU - Woodward, Jay TI - Significant changes to the International Building Code. SN - 9781952468186 AV - KF5701 I524 2021 PY - 2021/// CY - Washington, D.C. : PB - International Code Council KW - Housing KW - Law and legislation KW - Bulding laws KW - House construction KW - Standards N1 - Part 1 Administration Chapters 1 and 2 -- Chapter 1 Format of Administrative Provisions -- 110.3.5 Type IV Connection Protection -- 110.3.7 Inspection of Weather-Exposed Balconies -- 202 Definition of Atrium -- 202 Definition of Change of Occupancy -- 202 Definition of Impact Protective System -- 202 Definition of Mass Timber -- 202 Definition of Nailable Substrate -- 202 Definition of Penthouse -- 202 Definition of Puzzle Room -- 202 Definition of Structural Members -- PART 2 Building Planning -- Chapters 3 through 6 -- 306.2 Group F-1 Occupancy Classification -- 307.1.1 Uses Not Classified as Group H -- 311.2, 311.3 Alcoholic Beverage Storage -- 403.3.2 Water Supply to Required Fire Pumps -- 404.1 Scope of Atrium Provisions -- 404.5 Smoke Control in Atriums -- 404.6 Horizontal Assemblies in Atriums -- 406.2.4 Floor Surfaces in Parking Garages -- 407.3.1.1 Group 1-2 Corridor Doors -- 407.4.4.1, 407.4.4.3 Group 1-2 Care Suites -- 407.6.1 Automatic-Closing Doors in Group 1-2 -- 411.5 Puzzle Rooms -- 414.2.3 Fire Wall Use for Control Areas -- 422.7 Cooking in Ambulatory Care Facilities -- 424 Play Structures -- 503.1.4 Occupied Roof Allowances -- Table 504.3 Allowable Height in Feet -- Table 504.4 Allowable Height in Stories -- Table 506.2 Allowable Building Area -- 506.3.2 Allowable Area Frontage Increase -- 508.4.4 Separated Occupancies -- 508.4.4.1, 509.4.1.1 Fire Separations of Mass Timber -- 508.5 Live/Work Units -- Table 509.1 Storage Battery Systems as Incidental Uses -- 510.2 Stairway Construction in Podium Buildings -- Table 601 Type IV Fire-Resistance -- 602.4 Mass Timber Type IV Buildings -- 602.4.1-602.4.3 Type IV-A, IV-B and IV-C Buildings -- 602.4.4 Type IV-HT Buildings -- 603.1 Combustible Materials in Types I and II -- PART 3 Fire Protection -- Chapters 7 through 9 -- 703.6, 703.7 Noncombustible Protection for Mass Timber -- 704.6.1 Secondary Attachments and Fireproofing -- Table 705.5 Exterior Wall Ratings -- 707.4, 716 Separations of Energy Storage Systems -- 707.5 Enclosure of Exit Passageways -- 708.1, 708.4.1 Supporting Construction for Fire Partitions -- 709.4.1 Smoke Barrier Continuity -- 710.5.2.1, 710.5.3 Smoke Partition Openings -- 713.12 Top of Shaft Enclosure -- 715 Protection of Joints and Voids -- 716.2.2.1.1 Prohibited Use of Terminated Stops -- 716.4 Fire-Protective Curtain Assemblies -- Table 716.1(2) Doors in Double Fire Walls -- 717.2.3, 717.6.2.1 Ceiling Radiation Dampers -- 717.4 Access to Dampers -- 717.5.2 Flex Connectors -- 722.7 Fire-Resistance Rating of Mass Timber -- 806.9 Combustible Lockers as Interior Finish -- 903.2.4. 903.2.7, 903.2.9 Upholstered Furniture and Mattresses -- 903.2.4.2, 903.2.9.3 Distilled Spirits -- 903.2.10 Sprinklers in Parking Garages -- 903.2.10.2 Mechanical-Access Parking Garages -- 903.3.1.2 NFPA 13R Sprinkler Protection -- 903.3.1.2.2 Corridor and Balcony Sprinklers -- 905.3.1 Standpipes in Parking Garages -- 907.2.10 Manual Alarms in Group S Buildings -- 907.5.2.1.3 Fire Alarm Occupant Notification -- 909.20 Smokeproof Enclosures -- 911 Fire Command Centers in Groups F-1 and S-1 -- PART 4 Means of Egress Chapter 10 -- 1006.2.1 Egress from Mechanical Rooms and Penthouses -- 1006.3 Egress from Occupied Roofs -- 1006.3.4 Single Exit Stories -- 1008.2.1 Stairway Illumination -- 1009.2.1 Accessible Elevators to Occupied Roofs -- 1009.6.2 Areas of Refuge -- 1009.6.3, 3008.6.4 Area of Refuge Floor Space -- 1010.1.1 Door Widths -- 1010.1.1.1 Projections into Door Openings -- 1010.1.3 Door Opening Forces -- 1010.2.4 Locks and Latches -- 1010.2.8 Locking Arrangements in Group 1-4 -- 1011.6 Stairway Landings -- 1016.2 Egress Through Intervening Spaces -- 1019.3 Exit Access Stairways -- 1020.5 Dead-End Corridors -- 1030.16 Handrails at Social Stairs -- 1031 Emergency Escape and Rescue Openings -- PART 5 Accessibility -- Chapter 11 -- 1102 Accessible Design Compliance -- 1104.4 Accessible Multistory Buildings -- 1105.1.1 Automatic Doors at Public Entrances -- 1107.2 Vehicle Charging Stations -- 1108.5, 1110.2 Assisted Toileting and Bathing -- 1110.6 Bottle Filling Stations -- 1110.13.2 Service Windows -- 1110.15 Operable Parts -- PART 6 Building Envelope, Structural Systems, and Construction Materials -- Chapters 12 through 26 -- 1202.3 Insulation of Unvented Attics -- 1207 Enhanced Classroom Acoustics -- 1208.4 Efficiency Dwelling Units -- 1210.3 Restroom Privacy -- 1404.3 Vapor Retarders -- Table 1404.3.1 Class II Vapor Retarders -- 1404.3.2 Class III Vapor Retarders -- 1406.10 Metal Composite Material Cladding -- 1503.3 Parapet Walls -- 1504.5 Ballasted Roofs -- 1504.9 Aggregate-Surfaced Roofs -- 1603.1.4 Construction Document Wind Zones -- Table 1604.5 Risk Categories of Assembly Spaces -- 1605 Load Combinations -- 1606 Dead Loads -- 1607.11.4 Rope Descent Systems -- 1607.17 Fixed Ladder Live Load -- 1608.2 Snow Maps -- 1610.2 Soil-Caused Uplift -- 1611 Rain Loads -- 1612.4 Flood Hazard Documents -- 1704.6 Structural Observations -- Table 1705.3 Special Inspection of Precast Concrete -- 1705.4.1 Empirically Designed Masonry -- 1705.5.3, 1705.20 Mass Timber Special Inspection -- 1705.10 Structural Integrity of Deep Foundations -- 1705.13.7 Special Inspection of Storage Racks -- 1705.18 Firestop Inspections in Group R -- 1709.5 Window and Door Assemblies -- 1709.5.3 Impact Protection -- 1809.5.1 Frost Protection at Required Exits -- Table 1810.3.2.6 Allowable Stresses in Deep Foundations -- 1810.3.3.1.9 Helical Piles -- 1810.3.5.3.1 Structural Steel H-piles -- 1810.3.6 Deep Foundation Element Splicing -- 1810.3.8 Precast Concrete Piles -- 1810.3.11 Pile Caps -- 1810.4.5 Vibratory Drivers -- 1901.2 Concrete Design and Construction -- 1901.7 Structural Concrete Tolerances -- 2109.2.4.8 Exterior Finish of Adobe Masonry -- 2205.2.1 AISC 358 for Prequalified Connections -- 2209 Steel Storage Racks -- 2303.2 Fire-Retardant-Treated Wood -- 2303.4.1.2 Wood Truss Bracing -- 2304.10.1 Mass Timber Connection Protection -- Table 2304.10.2 Sheathing Fasteners -- 2304.11 Concealed Spaces in Type IV-HT -- 2305 Lateral Force-Resisting Systems -- 2308.5.6, 2308.6.6.2 Cripple Walls -- Table 2308.7.3.1 Rafter Tie Connections -- 2510.6 Water-Resistive Barriers for Stucco -- PART 7 Building Services, Special Devices, and Special Conditions -- Chapters 27 through 33 -- 2902 Minimum Plumbing Facilities -- 2902.3.3 Toilet Fixtures in Storage Facilities -- 3001.2 Emergency Elevator Communication Systems -- 3103.1 Special Event Structures -- 3114 Public Use Restrooms in Flood Hazard Areas -- 3115 Intermodal Shipping Containers -- 3313 Fire Protection During Construction -- PART 8 Appendices Appendices A through 0 -- Appendix B Board of Appeals -- Appendix O Application of ICC Performance Code -- PART 9 2021 International Existing Building Code (IEBC) -- Chapters 1 through 16 and Appendices A through C -- 303 Storm Shelters -- 306.7 Accessible Toilet and Bathing Rooms -- 307, 308 Smoke Alarms and CO Detection -- 309 Exterior Wall Coverings and Envelopes - 405.2.4 Snow Loads and Substantial Damag-e 502.6, 503.16, 506.6 Classroom Acoustics -- 503.4 Rooftop Equipment Dead Load -- 503.12, 706.3.2 Roof Diaphragm Wind Loads -- 503.17, 704.3 Locking in Educational Occupancies -- 506.4, 1011.5.1, 1011.5.6 Emergency Escape and Rescue Openings -- 506.5.3, 1006.3 Change of Occupancy from Group S or U -- 603.1, 704, 801.3 Furniture and Equipment -- 704.1.1 Seating in Nursing Home Corridors -- 803.2.2, 803.2.3, 803.2.5 Sprinklers and Level 2 Alterations -- 904.1.4, 904.1.5, 904.1.6, 904.1.7 Sprinklers and Level 3 Alterations -- 1002.1, 1002.2 Special Uses and Incidental Uses -- 1011.1, 1011.2 Change of Occupancy Applicability -- ER -