<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>09027nam a22003137a 4500</leader>
  <controlfield tag="003">pucpr</controlfield>
  <controlfield tag="005">20210714152334.0</controlfield>
  <controlfield tag="008">210708b2021       ao||| |||| 00| 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">9781952468186</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">pucpr</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">pucpr</subfield>
    <subfield code="d">pucpr</subfield>
    <subfield code="e">rda</subfield>
  </datafield>
  <datafield tag="049" ind1=" " ind2=" ">
    <subfield code="a">CARIBET</subfield>
  </datafield>
  <datafield tag="050" ind1=" " ind2=" ">
    <subfield code="a">KF5701</subfield>
    <subfield code="b">I524 2021</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="9">296220</subfield>
    <subfield code="a">Thornburg, Douglas W.</subfield>
    <subfield code="e">AIA, CBO</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Significant changes to the International Building Code. /</subfield>
    <subfield code="c">Douglas W. Thornburg, AIA, CBO ; Sandra Hyde, P.E. ; Jay Woodward</subfield>
    <subfield code="h">txt</subfield>
  </datafield>
  <datafield tag="250" ind1=" " ind2=" ">
    <subfield code="a">2021 Edition</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2=" ">
    <subfield code="a">Washington, D.C. : </subfield>
    <subfield code="b">International Code Council,</subfield>
    <subfield code="c">2021.</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">410 pages : </subfield>
    <subfield code="b">ill. ; col. ;photo ; </subfield>
    <subfield code="c">28 cm.</subfield>
    <subfield code="f">book</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="2">rdacontent</subfield>
    <subfield code="a">text</subfield>
    <subfield code="b">txt</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="2">rdamedia</subfield>
    <subfield code="a">unmediaded</subfield>
    <subfield code="b">n</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="2">rdacarrier</subfield>
    <subfield code="a">volume</subfield>
    <subfield code="b">nc</subfield>
  </datafield>
  <datafield tag="440" ind1=" " ind2=" ">
    <subfield code="9">296229</subfield>
    <subfield code="a">The International Codes</subfield>
  </datafield>
  <datafield tag="505" ind1=" " ind2=" ">
    <subfield code="a">Part 1 Administration Chapters 1 and 2 --
Chapter 1 Format of Administrative Provisions --
110.3.5 Type IV Connection Protection --
110.3.7 Inspection of Weather-Exposed Balconies --
202 Definition of Atrium --
202 Definition of Change of Occupancy --
202 Definition of Impact Protective System --
202 Definition of Mass Timber --
202 Definition of Nailable Substrate --
202 Definition of Penthouse --
202 Definition of Puzzle Room --
202 Definition of Structural Members --
PART 2 Building Planning --
Chapters 3 through 6 --
306.2 Group F-1 Occupancy Classification --
307.1.1 Uses Not Classified as Group H --
311.2, 311.3 Alcoholic Beverage Storage --
403.3.2 Water Supply to Required Fire Pumps --
404.1 Scope of Atrium Provisions --
404.5 Smoke Control in Atriums --
404.6 Horizontal Assemblies in Atriums --
406.2.4 Floor Surfaces in Parking Garages --
407.3.1.1 Group 1-2 Corridor Doors --
407.4.4.1, 407.4.4.3 Group 1-2 Care Suites --
407.6.1 Automatic-Closing Doors in Group 1-2 --
411.5 Puzzle Rooms --
414.2.3 Fire Wall Use for Control Areas --
422.7 Cooking in Ambulatory Care Facilities --
424 Play Structures --
503.1.4 Occupied Roof Allowances --
Table 504.3 Allowable Height in Feet --
Table 504.4 Allowable Height in Stories --
Table 506.2 Allowable Building Area --
506.3.2 Allowable Area Frontage Increase --
508.4.4 Separated Occupancies --
508.4.4.1, 509.4.1.1 Fire Separations of Mass Timber --
508.5 Live/Work Units --
Table 509.1 Storage Battery Systems as Incidental Uses --
510.2 Stairway Construction in Podium Buildings --
Table 601 Type IV Fire-Resistance --
602.4 Mass Timber Type IV Buildings --
602.4.1-602.4.3 Type IV-A, IV-B and IV-C Buildings --
602.4.4 Type IV-HT Buildings --
603.1 Combustible Materials in Types I and II --
PART 3 Fire Protection --
Chapters 7 through 9 --
703.6, 703.7 Noncombustible Protection for Mass Timber --
704.6.1 Secondary Attachments and Fireproofing --
Table 705.5 Exterior Wall Ratings --
707.4, 716 Separations of Energy Storage Systems --
707.5 Enclosure of Exit Passageways --
708.1, 708.4.1 Supporting Construction for Fire Partitions --
709.4.1 Smoke Barrier Continuity --
710.5.2.1, 710.5.3 Smoke Partition Openings --
713.12 Top of Shaft Enclosure --
715 Protection of Joints and Voids --
716.2.2.1.1 Prohibited Use of Terminated Stops --
716.4 Fire-Protective Curtain Assemblies --
Table 716.1(2) Doors in Double Fire Walls --
717.2.3, 717.6.2.1 Ceiling Radiation Dampers --
717.4 Access to Dampers --
717.5.2 Flex Connectors --
722.7 Fire-Resistance Rating of Mass Timber --
806.9 Combustible Lockers as Interior Finish --
903.2.4. 903.2.7, 903.2.9 Upholstered Furniture and Mattresses --
903.2.4.2, 903.2.9.3 Distilled Spirits --
903.2.10 Sprinklers in Parking Garages --
903.2.10.2 Mechanical-Access Parking Garages --
903.3.1.2 NFPA 13R Sprinkler Protection --
903.3.1.2.2 Corridor and Balcony Sprinklers --
905.3.1 Standpipes in Parking Garages --
907.2.10 Manual Alarms in Group S Buildings --
907.5.2.1.3 Fire Alarm Occupant Notification --
909.20 Smokeproof Enclosures --
911 Fire Command Centers in Groups F-1 and S-1 --
PART 4 Means of Egress Chapter 10 --
1006.2.1 Egress from Mechanical Rooms and Penthouses --
1006.3 Egress from Occupied Roofs --
1006.3.4 Single Exit Stories --
1008.2.1 Stairway Illumination --
1009.2.1 Accessible Elevators to Occupied Roofs --
1009.6.2 Areas of Refuge --
1009.6.3, 3008.6.4 Area of Refuge Floor Space --
1010.1.1 Door Widths --
1010.1.1.1 Projections into Door Openings --
1010.1.3 Door Opening Forces --
1010.2.4 Locks and Latches --
1010.2.8 Locking Arrangements in Group 1-4 --
1011.6 Stairway Landings --
1016.2 Egress Through Intervening Spaces --
1019.3 Exit Access Stairways --
1020.5 Dead-End Corridors --
1030.16 Handrails at Social Stairs --
1031 Emergency Escape and Rescue Openings --
PART 5 Accessibility --
Chapter 11 --
1102 Accessible Design Compliance --
1104.4 Accessible Multistory Buildings --
1105.1.1 Automatic Doors at Public Entrances --
1107.2 Vehicle Charging Stations --
1108.5, 1110.2 Assisted Toileting and Bathing --
1110.6 Bottle Filling Stations --
1110.13.2 Service Windows --
1110.15 Operable Parts --
PART 6 Building Envelope, Structural Systems, and Construction Materials --
Chapters 12 through 26 --
1202.3 Insulation of Unvented Attics --
1207 Enhanced Classroom Acoustics --
1208.4 Efficiency Dwelling Units --
1210.3 Restroom Privacy --
1404.3 Vapor Retarders --
Table 1404.3.1 Class II Vapor Retarders --
1404.3.2 Class III Vapor Retarders --
1406.10 Metal Composite Material Cladding --
1503.3 Parapet Walls --
1504.5 Ballasted Roofs --
1504.9 Aggregate-Surfaced Roofs --
1603.1.4 Construction Document Wind Zones --
Table 1604.5 Risk Categories of Assembly Spaces --
1605 Load Combinations --
1606 Dead Loads --
1607.11.4 Rope Descent Systems --
1607.17 Fixed Ladder Live Load --
1608.2 Snow Maps --
1610.2 Soil-Caused Uplift --
1611 Rain Loads --
1612.4 Flood Hazard Documents --
1704.6 Structural Observations --
Table 1705.3 Special Inspection of Precast Concrete --
1705.4.1 Empirically Designed Masonry --
1705.5.3, 1705.20 Mass Timber Special Inspection --
1705.10 Structural Integrity of Deep Foundations --
1705.13.7 Special Inspection of Storage Racks --
1705.18 Firestop Inspections in Group R --
1709.5 Window and Door Assemblies --
1709.5.3 Impact Protection --
1809.5.1 Frost Protection at Required Exits --
Table 1810.3.2.6 Allowable Stresses in Deep Foundations --
1810.3.3.1.9 Helical Piles --
1810.3.5.3.1 Structural Steel H-piles --
1810.3.6 Deep Foundation Element Splicing --
1810.3.8 Precast Concrete Piles --
1810.3.11 Pile Caps --
1810.4.5 Vibratory Drivers --
1901.2 Concrete Design and Construction --
1901.7 Structural Concrete Tolerances --
2109.2.4.8 Exterior Finish of Adobe Masonry --
2205.2.1 AISC 358 for Prequalified Connections --
2209 Steel Storage Racks --
2303.2 Fire-Retardant-Treated Wood --
2303.4.1.2 Wood Truss Bracing --
2304.10.1 Mass Timber Connection Protection --
Table 2304.10.2 Sheathing Fasteners --
2304.11 Concealed Spaces in Type IV-HT --
2305 Lateral Force-Resisting Systems --
2308.5.6, 2308.6.6.2 Cripple Walls --
Table 2308.7.3.1 Rafter Tie Connections --
2510.6 Water-Resistive Barriers for Stucco --
PART 7 Building Services, Special Devices, and Special Conditions --
Chapters 27 through 33 --
2902 Minimum Plumbing Facilities --
2902.3.3 Toilet Fixtures in Storage Facilities --
3001.2 Emergency Elevator Communication Systems --
3103.1 Special Event Structures --
3114 Public Use Restrooms in Flood Hazard Areas --
3115 Intermodal Shipping Containers --
3313 Fire Protection During Construction --
PART 8 Appendices Appendices A through 0 --
Appendix B Board of Appeals --
Appendix O Application of ICC Performance Code --
PART 9 2021 International Existing Building Code (IEBC) --
Chapters 1 through 16 and Appendices A through C --
303 Storm Shelters --
306.7 Accessible Toilet and Bathing Rooms --
307, 308 Smoke Alarms and CO Detection --
309 Exterior Wall Coverings and Envelopes -
405.2.4 Snow Loads and Substantial Damag-e
502.6, 503.16, 506.6 Classroom Acoustics --
503.4 Rooftop Equipment Dead Load --
503.12, 706.3.2 Roof Diaphragm Wind Loads --
503.17, 704.3 Locking in Educational Occupancies --
506.4, 1011.5.1, 1011.5.6 Emergency Escape and Rescue Openings --
506.5.3, 1006.3 Change of Occupancy from Group S or U --
603.1, 704, 801.3 Furniture and Equipment --
704.1.1 Seating in Nursing Home Corridors --
803.2.2, 803.2.3, 803.2.5 Sprinklers and Level 2 Alterations --
904.1.4, 904.1.5, 904.1.6, 904.1.7 Sprinklers and Level 3 Alterations --
1002.1, 1002.2 Special Uses and Incidental Uses --
1011.1, 1011.2 Change of Occupancy Applicability --
</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="9">112622</subfield>
    <subfield code="a">Housing</subfield>
    <subfield code="x">Law and legislation</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="9">205681</subfield>
    <subfield code="a">Bulding laws.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="9">112574</subfield>
    <subfield code="a">House construction</subfield>
    <subfield code="x">Standards</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="9">298506</subfield>
    <subfield code="a">Hyde, Sandra</subfield>
    <subfield code="e">P.E.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="9">298514</subfield>
    <subfield code="a">Woodward, Jay</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">6</subfield>
    <subfield code="e">2021 Edition</subfield>
    <subfield code="h">KF5701</subfield>
    <subfield code="k">Referencia</subfield>
    <subfield code="m">I524 2021</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">296550</subfield>
    <subfield code="d">296550</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">4</subfield>
    <subfield code="b">4</subfield>
    <subfield code="c">30</subfield>
    <subfield code="d">2021-06-18</subfield>
    <subfield code="e">Amazon</subfield>
    <subfield code="g">66.90</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">Referencia KF5701 I524 2021</subfield>
    <subfield code="p">91000000064808</subfield>
    <subfield code="r">2023-09-11 11:42:49</subfield>
    <subfield code="t">1</subfield>
    <subfield code="v">76.90</subfield>
    <subfield code="w">2021-06-18</subfield>
    <subfield code="y">37</subfield>
  </datafield>
</record>
