Van Note, Stephen A.

Significant changes to the International Residential Code, 2021 edition txt Stephen A. Van Note ; Sandra Hyde, P.E. - 2021 edition - 287 p. ill. ; photo. ; col. ; 28 cm. book

PART 1 Administration Chapters 1 and 2 --
R102.7.1 Additions, Alterations or Repairs --
R202 Definition of Emergency Escape and Rescue Opening --
R202 Definition of Townhouse --
PART 2 Building Planning Chapter 3 --
R301.1.4 Intermodal Shipping Containers --
R301.2 Wind Speeds --
Table R301.2.1(1) Component and Cladding Wind Pressures --
R301.2.1.1 Special Wind Regions --
R301.2.2.6 Irregular Buildings in Seismic Areas --
R301.2.2.10 Seismic Anchorage of Water Heaters --
R301.3 Story Height --
R302.2 Townhouses --
R302.3 Two-Family Dwelling Separation --
R302.4 Dwelling Unit Rated Penetrations --
R302.5 Dwelling-Garage Opening Protection --
R303.1 Mechanical Ventilation --
R305.1 Ceiling Height--
R308.4.5 Glazing and Wet Surfaces --
R308.6 Skylight Glass Retention Screens --
R310.1 Emergency Escape and Rescue Opening Required --
R310.2 Emergency Escape and Rescue Openings --
R310.3, R310.4 Area Wells for Emergency Escape and Rescue Openings --
R310.5, 8310.6, 8310.7 Emergency Escape and Rescue Openings in Existing Buildings --
R311.7, R311.8 Stairways and Ramps --
R311.7.7 Stairway and Landing Walking Surface --
R312.2 Window Fall Protection --
R314.3 Smoke Alarm Locations --
R315.2.2 Carbon Monoxide Alarms --
R317.1 Protection of Wood Against Decay --
R320 Accessibility --
R323 Storm Shelters --
R324.3 Photovoltaic Systems --
R326 Habitable Attics --
PART 3 Building Construction Chapters 4 through 10 --
Table R403.1(1) Footings Below Light-Frame Construction --
R406.2 Foundation Waterproofing --
R408.8 Vapor Retarder in Crawlspaces --
R506.2.3 Vapor Retarders Under Concrete Slabs --
R507 Deck Loads --
R507.3 Deck Footings --
R507.4 Deck Posts --
R507.5 Deck Beams --
R507.5 Deck Joists --
R507.7 Decking --
R507.10 Exterior Guards --
Table R602.3(1) Fasteners — Roof and Wall --
Table R602.3(1) Fasteners — Roof Sheathing --
Table R602.3(2) Alternate Attachments --
R602.9 Cripple Walls --
R602.10.1.2 Location of Braced Wall Lines --
R602.10.2.2 Location of Braced Wall Panels (BWPs) --
R602.10.3(1) Bracing for Winds --
Table R602.10.3(3) Seismic Wall Bracing --
Table R602.10.3(4) Adjustment Factors — Seismic --
R602.10.6.5 Stone and Masonry Veneer --
R609.4.1 Garage Doors --
R702.7 Vapor Retarders --
R703.2, R703.7.3 Water-Resistive Barriers --
Table R703.8.4(1) Veneer Attachment --
R703.11.2 Vinyl Siding Installation Over Foam Plastic Sheathing --
R704 Soffits --
R802 Wood Roof Framing --
Table R802.5.2(1) Heel Joint Connections --
R802.6 Rafter and Ceiling Joist Bearing --
Table R804.3 CFS Roof Framing Fasteners --
R905.4.4.1 Metal Roof Shingle Wind Resistance --
PART 4 Energy Conservation Chapter 11 --
N1101.6 Definition of High-Efficacy Light Sources --
N1101.7 Climate Zones --
N1101.13 Compliance Options --
N1101.13.5 Additional Energy Efficiency Requirements --
N1101.14 Permanent Energy Certificate --
N1102.1 Building Thermal Envelope --
Tables N1102.1.2 and N1102.1.3 Insulation and Fenestration Requirements --
N1102.2 Ceiling Insulation --
N1102.2.4 Access Hatches and Doors --
N1102.2.7 R-Value Reduction for Walls with Partial Structural Sheathing --
N1102.2.7 Floor Insulation --
N1102.2.8 Unconditioned Basement --
N1102.4 and Table N1102.4.1.1 Building Air Leakage and Testing --
N1102.4.6 Air-Sealed Electrical Boxes --
N1103.3 Duct Installation --
N1103.3.5 Duct Testing 205
N1103.6 Mechanical Ventilation --
N1104 Lighting Equipment --
N1105 and Table N1105.2 Total Building Performance Analysis --
N1106 and Table N1106.2 Energy Rating Index Analysis --
N1108 Additional Efficiency Package Options --
PART 5 Mechanical Chapters 12 through 23 --
M1505 Balanced Ventilation System Credit --
M1802.4 Blocked Vent Switch for Oil-fired Appliances --
M2101 Hydronic Piping Systems Installation --
PART 6 Fuel Gas Chapter 24 --
G2403 Definitions of Point of Delivery and Service Meter Assembly --
G2414.8.3 Threaded Joint Sealing --
G2415.5 Fittings in Concealed Locations --
G2427.5.5.1 Chimney Lining --
G2427.8 Through-the-wall Vent Terminal Clearances --
G2439.5 Makeup Air for Dryer Installed in a Closet --
G2447.2 Commercial Cooking Appliances Prohibited
PART 7 Plumbing Chapters 25 through 33 --
P2503.5.1 Drain, Waste and Vent Systems Testing --
P2708.4, P2713.3 Shower and Bathtub Control Valves --
P2904 Installation Practices for Residential Sprinklers --
P2905.3 Length of Hot Water Piping to Fixtures --
P3005.2.10.1 Removable Fixture Traps as Cleanouts --
P3011 Relining of Building Sewers and Building Drains --
PART 8 Electrical Chapters 34 through 43 --
E3601.8 Emergency Service Disconnects --
E3606.5 Service Surge-Protective Device --
E3703.4 Bathroom Branch Circuits --
E3703.5 Garage Branch Circuits --
E3901.4 Kitchen Countertop and Work Surface Receptacles --
E3902 GFCI Protection for 250-Volt Receptacles --
E3902.5 GFCI Protection for Basement Receptacles --
E3902.10 GFCI Protection for Indoor Damp and \Vet Locations --
PART 9 Appendices Appendix A through W --
AF104 Radon Testing --
Appendix AU Cob Construction --
Appendix AW 3D Printed Buildings --

9781952468193 9781955052443


Building laws
Construction industry--Standards.
House construction--Standards.
Standards, Engineering.

TH420 / N32 2021