TY - BOOK AU - Grable, Fred AU - Gress, Gregg TI - Significant changes to the International Plumbing Code, International Mechanical Code, International Fuel Gas Code. SN - 9781952468216 AV - TH6123 G73 2020 PY - 2020/// CY - Washington, D.C. : PB - International Code Council KW - Plumbing KW - Standards KW - Building KW - Mechanical equipment KW - Gas fitting N1 - SIGNIFICANT CHANGES TO THE International Plumbing Code -- PART 1 International Plumbing Code -- Chapters 1 through 15 -- 202 Definition of Copper Alloy -- 202 Definition of Public and Private -- 202 Definition of Water Dispenser -- 308.9 Bundled Hot Water Piping Insulation -- 403.1.1 Fixture Quantity Calculations for Multiple User Facilities -- 403.1.2 Fixtures in Single-user Toilet Rooms Count Towards Total Required Quantities -- 403.2 Multiple-user Nonseparated Toilet Facilities -- 403.3.1, 403.5 Facilities and Drinking Fountains on Accessible Routes -- 403.3.3 Group S Toilet Facility Location -- 403.6 Service Sink Location -- 405.4.3 Wall Hung Fixture Carrier Standard for Water Closets -- 407.2 Bathtubs are Not Required to have Overflow Outlets -- 410.3.2 Quantities of Standing versus Wheelchair Drinking Fountains -- 410.4 Drinking Fountain Substitution using Water Dispensers -- 411.3 Water Heaters for Emergency Showers and Eye Wash Stations -- 412.3 Shower Control Valves to be Rated for the Installed Shower Head -- 412.5 Methods for Limiting Water Temperature Discharged to Bathtubs -- 412.10 Methods for Temperature Limitation at Head Shampoo Sinks and Footbaths -- 419.5 Tempered Water for Public Hand-Washing Lavatories -- 421.3.1 Standard for Shower Waste Fittings -- 501.2 ASSE 1017 Temperature Actuated Mixing Valves -- 602.3.5 Potable Water Pumps to Comply with NSF61 -- 605.12.3, 605.13.6 Solder and Flux to Conform to NSF61 -- 606.1 Individual Tenant Water Shut-off Valve -- 607.1.1, 607.1.2 Water Heaters Providing Tempered Water to Fixtures -- 608.15.2.1 Discharge from Backflow Preventer Relief Opening -- 608.17.2 Backflow Device for Low Hazard Boiler Applications -- 609.2 Two Water Service Pipes for Group 1-2, Condition 2 Healthcare Facilities -- 609.2.1 Tracer Wire for Buried Nonmetallic Water Service Piping -- Table 702.3 ABS Building Sewer Pipe Standard -- 705.2.4, 705.10.4 PVC and ABS Push-fit DWV Fittings -- 708.1.6 Removable Fixture Traps Serving as Cleanouts -- 717, 718 Methods for Restoring Building Sewer Piping -- 903.1.3 Protected Outdoor Vent Termination Method -- 915.1 Food Waste Disposers on Combination Waste and Vent Systems -- 1002.1 Direct Connection to Hydromechanical Grease Interceptor -- 1002.4.1.5 Fixture Drains Serving as a Trap Priming Method -- 1102.6 Roof Drains to be Tested and Rated for Flow -- 1106.2.1 Rainfall Rate Conversion Method -- 1202.1 Nonflammable Medical Gas Systems -- 1301.1 Nonpotable Rainwater Standard Alternative --; SIGNIFICANT CHANGES TO THE International Mechanical Code -- PART 2 International Mechanical Code -- Chapters 1 through 15 -- 307.2.1.1 Condensate Discharge -- 401.2, 403.1 Mechanical Ventilation for Dwelling Units -- 401.4, 501.3.1 Intake Opening and Exhaust Outlet Locations -- Table 403.3.1.1 Recirculation of Mechanical Exhaust Prohibited -- 403.3.1.3 Demand Controlled Ventilation -- 403.3.2.1 Outdoor Air for Dwelling Units -- 502.20 Manicure and Pedicure Station Exhaust System -- 504.4.1 Termination Location for Dryer Exhaust -- 506.3.7 Factory-Built Grease Duct Slope -- 507.1 Smoker Ovens with Integral Exhaust -- 514.2 Energy Recovery Ventilation Systems -- 602.2.1.8 Pipe and Duct Insulation Within Plenums -- 607.5.2 Duct Penetrations of Fire Barriers -- 607.5.5 Subducts Penetrating Shaft Enclosures -- 608.1, 403.3.1.5 Ventilation Air Distribution -- 801.21 Blocked Vent Switch for Oil-Fired Appliance -- 905.1 Wood-Burning Residential Hydronic Heaters -- 929 Unvented Alcohol Fuel-Burning Decorative Appliances -- 1101 through 1108 Ammonia Refrigeration Systems -- 1105.9 Machinery Room Means of Egress -- 1107 through 1110 Refrigerant Piping --; SIGNIFICANT CHANGES TO THE International Fuel Gas Code -- PART 3 International Fuel Gas Code Chapters 1 through 8 -- 202 Definition of Point of Delivery -- 307.2 Concealed Condensate Piping -- 402.7, 202 Press-Connect Joint -- 403.8.3 Threaded Joint Sealing -- 404.5 Fittings in Concealed Locations -- 503.5.6.1 Chimney Lining -- 503.8 Venting System Terminal Clearances -- 503.10.7 Vent Connector Junctions -- 614.7 Clothes Dryer Makeup Air -- 618.6 Return Air from Mechanical Room -- 623.2 Commercial Cooking Appliances -- ER -