TY - BOOK ED - International Code Council TI - 2021 IFGC : : International Fuel Gas Code SN - 1609839668 AV - KF5704 I58 2020 U1 - 343.0786962 23 PY - 2020/// CY - Country Club Hills, IL PB - International Code Council KW - Gas KW - Law and legislation KW - Local KW - Construction KW - Ventilation KW - Natural gas pipelines KW - Safety regulations KW - Gas pipelines KW - Gas fitting KW - Gases KW - Fuel KW - Building laws N1 - Includes index; CHAPTER 1 SCOPE AND ADMINISTRATION -- PART 1—SCOPE AND APPLICATION-- 101 Scope and General Requirements (IFGC) -- 102 Applicability (IFGC) -- PART 2—ADMINISTRATION AND ENFORCEMENT -- 103 Code Compliance Agency (IFGC) -- 104 Duties and Powers of the Code Official (IFGC) -- 105 Approval (IFGC) -- 106 Permits (IFGC) -- 107 Construction Documents (IFGC) -- 108 Notice of Approval (IFGC) -- 109 Fees (IFGC) -- 110 Service Utilities (IFGC) -- 111 Temporary Equipment, Systems and Uses (IFGC) -- 112 Inspections and Testing (IFGC) -- 113 Means of Appeal (IFGC) -- 114 Board of Appeals (IFGC) -- 115 Violations (IFGC) -- 116 Stop Work Order (IFGC) -- CHAPTER 2 DEFINITIONS -- 201 General (IFGC) -- 202 General Definitions (IFGC) -- CHAPTER 3 GENERAL REGULATIONS -- 301 General (IFGC) -- 302 Structural Safety (IFGC) -- 303 Appliance Location (IFGC) -- 304 Combustion, Ventilation and Dilution Air (IFGS) -- 305 Installation (IFGC) -- 306 Access and Service Space (IFGC) -- 307 Condensate Disposal (IFGC) -- 308 Clearance Reduction (IFGS) -- 309 Electrical (IFGC) -- 310 Electrical Bonding (IFGS) -- CHAPTER 4 GAS PIPING INSTALLATIONS -- 401 General (IFGC) -- 402 Pipe Sizing (IFGS) -- 403 Piping Materials (IFGS) -- 404 Piping System Installation (IFGC) -- 405 Piping Bends and Changes in Direction (IFGS) -- 406 Inspection, Testing and Purging (IFGS) -- 407 Piping Support (IFGC) -- 408 Drips and Sloped Piping (IFGC) -- 409 Shutoff Valves (IFGC) -- 410 Flow Controls (IFGC) -- 411 Appliance and Manufactured Home Connections (IFGC) -- 412 Liquefied Petroleum Gas Motor Vehicle Fuel-dispensing Facilities (IFGC) -- 413 Compressed Natural Gas Motor Vehicle Fuel-dispensing Facilities (IFGC) -- 414 Supplemental and Standby Gas Supply (IFGC) -- 415 Piping Support Intervals (IFGS) -- 416 Overpressure Protection Devices (IFGS) -- CHAPTER 5 CHIMNEYS AND VENTS -- 501 General (IFGC) -- 502 Vents (IFGC) -- 503 Venting of Appliances (IFGS) -- 504 Sizing of Category I Appliance Venting Systems (IFGS) -- 505 Direct-vent, Integral Vent, Mechanical Vent and Ventilation/Exhaust Hood Venting (IFGC) -- 506 Factory-built Chimneys (IFGC) -- CHAPTER 6 SPECIFIC APPLIANCES -- 601 General (IFGC) -- 602 Decorative Appliances for Installation in Fireplaces (IFGC) -- 603 Log Lighters (IFGC) -- 604 Vented Gas Fireplaces (Decorative Appliances) (IFGC) -- 605 Vented Gas Fireplace Heaters (IFGC) -- 606 Incinerators and Crematories (IFGC) -- 607 Commercial-industrial Incinerators (IFGC) -- 608 Vented Wall Furnaces (IFGC) -- 609 Floor Furnaces (IFGC) -- 610 Duct Furnaces (IFGC) -- 611 Nonrecirculating Direct-fired Industrial Air Heaters (IFGC) -- 612 Recirculating Direct-fired Industrial Air Heaters (IFGC) -- 613 Clothes Dryers (IFGC) -- 614 Clothes Dryer Exhaust (IFGC) -- 615 Sauna Heaters (IFGC) -- 616 Engine and Gas Turbine-powered Equipment (IFGC) -- 617 Pool and Spa Heaters (IFGC) -- 618 Forced-air Warm-air Furnaces (IFGC) -- 619 Conversion Burners (IFGC) -- 620 Unit Heaters (IFGC) -- 621 Unvented Room Heaters (IFGC) -- 622 Vented Room Heaters (IFGC) -- 623 Cooking Appliances (IFGC) -- 624 Water Heaters (IFGC) -- 625 Refrigerators (IFGC) -- 626 Gas-fired Toilets (IFGC) -- 627 Air-conditioning Appliances (IFGC) -- 628 Illuminating Appliances (IFGC) -- 629 Small Ceramic Kilns (IFGC) -- 630 Infrared Radiant Heaters (IFGC) -- 631 Boilers (IFGC) -- 632 Equipment Installed in Existing Unlisted Boilers (IFGC) -- 633 Stationary Fuel-cell Power Systems (IFGC) -- 634 Gaseous Hydrogen Systems (IFGC) 635 Outdoor Decorative Appliances (IFGC) CHAPTER 7 GASEOUS HYDROGEN SYSTEMS -- 701 General (IFGC) -- 702 General Definitions (IFGC) -- 703 General Requirements (IFGC) -- 704 Piping, Use and Handling (IFGC) -- 705 Testing of Hydrogen Piping Systems (IFGC) -- 706 Location of Gaseous Hydrogen Systems (IFGC) -- 707 Operation and Maintenance of Gaseous Hydrogen Systems (IFGC) -- 708 Design of Liquefied Hydrogen Systems Associated with Hydrogen Vaporization Operations (IFGC) -- CHAPTER 8 REFERENCED STANDARDS -- APPENDIX A SIZING AND CAPACITIES OF GAS PIPING (IFGS) -- A101 General Piping Considerations -- A102 Description of Tables -- A103 Use of Capacity Tables -- A104 Use of Sizing Equations -- A105 Pipe and Tube Diameters -- A106 Examples of Piping System Design and Sizing -- APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS (IFGS) -- B101 Examples Using Single-appliance Venting Tables -- B102 Examples Using Common Venting Tables -- APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS (IFGS) -- C101 General -- APPENDIX D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION (IFGS) -- D101 General -- D102 Occupant and Inspector Safety -- D103 Gas Piping and Connections Inspections -- D104 Inspections to be Performed with the Appliance not Operating -- D105 Inspections to be Performed with the Appliance Operating -- D106 Appliance-specific Inspections -- APPENDIX E BOARD OF APPEALS -- 101 General -- INDEX. ER -