Imagen de portada de Amazon
Imagen de Amazon.com
Imagen de cubierta Syndetics
Portada de Syndetics
Imagen de OpenLibrary

IBC a member of the International Code Family

Por: Series The International Codes. 2018 Country Club Hills, IL International Code Council 2017Edición: August 31, 2017Descripción: 725 p. : ill. 28 cmTipo de contenido:
  • txt
Tipo de medio:
  • unmediaded
Tipo de soporte:
  • volume
ISBN:
  • 9781609837358
  • 9781609837341
Otro título:
  • International building code 2018
  • 2018 International Codes
Tema(s): Clasificación LoC:
  • KF5701 I58 2017
Valoración
    Valoración media: 0.0 (0 votos)
Existencias
Imagen de cubierta Tipo de ítem Biblioteca actual Biblioteca de origen Colección Ubicación en estantería Signatura topográfica Materiales especificados Info Vol URL Copia número Estado Notas Fecha de vencimiento Código de barras Reserva de ítems Prioridad de la cola de reserva de ejemplar Reservas para cursos
Libro Referencia CARIBET CARIBET Biblioteca Arquitectura Colección de Referencia CARIBET Referencia KF5701 I58 2017 (Navegar estantería(Abre debajo)) 1 Disponible 91000000057356
Total de reservas: 0

Descripciones mejoradas de Syndetics:

This code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2018 IBC contains many important changes such as: Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory. New code sections have been introduced addressing medical gas systems and higher education laboratories. Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height. Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway. The occupant load factor for business uses has been revised to one occupant per 150 square feet. Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served. The minimum lateral load that fire walls are required to resist is five pounds per square foot. Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds. Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values). Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed. New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail. Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.

Includes index.

Compartir
logopucpr-y-vive

Contáctanos

¡Queremos saber de ti!

Tel. 787.841.2000 Ext. 1801

bibliotecavaldes@pucpr.edu

⁣Búscanos en las redes

© 2026 Desarrollado por Ignite Online • All Rights Reserved • Powered by Koha.