Significant changes to the International Plumbing Code, International Mechanical Code, International Fuel Gas Code. / (Registro nro. 296515)

Detalles MARC
000 -LEADER
fixed length control field 05407nam a22003257a 4500
003 - CONTROL NUMBER IDENTIFIER
control field pucpr
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210708140011.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210708b20202021 ao||| |||| 00| 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9781952468216
International Standard Book Number 1952468213
040 ## - CATALOGING SOURCE
Original cataloging agency pucpr
Language of cataloging eng
Transcribing agency pucpr
Modifying agency pucpr
Description conventions rda
049 ## - LOCAL HOLDINGS
Holding library CARIBET
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number TH6123
Item number G73 2020
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 298485
Personal name Grable, Fred
245 ## - TITLE STATEMENT
Title Significant changes to the International Plumbing Code, International Mechanical Code, International Fuel Gas Code. /
Statement of responsibility, etc. Fred Grable, Gregg Gress.
Medium txt
264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Washington, D.C. :
Name of producer, publisher, distributor, manufacturer International Code Council,
Date of production, publication, distribution, manufacture, or copyright notice 2020.
300 ## - PHYSICAL DESCRIPTION
Extent x, 123 pages :
Other physical details ill. ; col. ;photo ;
Dimensions 28 cm.
Type of unit book
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
Content type code txt
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediaded
Media type code n
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
Carrier type code nc
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE
9 (RLIN) 296229
Title The International Codes
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note SIGNIFICANT CHANGES TO THE International Plumbing Code --<br/>PART 1 International Plumbing Code --<br/>Chapters 1 through 15 --<br/>202 Definition of Copper Alloy --<br/>202 Definition of Public and Private --<br/>202 Definition of Water Dispenser --<br/>308.9 Bundled Hot Water Piping Insulation --<br/>403.1.1 Fixture Quantity Calculations for Multiple User Facilities --<br/>403.1.2 Fixtures in Single-user Toilet Rooms Count Towards Total Required Quantities --<br/>403.2 Multiple-user Nonseparated Toilet Facilities --<br/>403.3.1, 403.5 Facilities and Drinking Fountains on Accessible Routes --<br/>403.3.3 Group S Toilet Facility Location --<br/>403.6 Service Sink Location --<br/>405.4.3 Wall Hung Fixture Carrier Standard for Water Closets --<br/>407.2 Bathtubs are Not Required to have Overflow Outlets --<br/>410.3.2 Quantities of Standing versus Wheelchair Drinking Fountains --<br/>410.4 Drinking Fountain Substitution using Water Dispensers --<br/>411.3 Water Heaters for Emergency Showers and Eye Wash Stations --<br/>412.3 Shower Control Valves to be Rated for the Installed Shower Head -- <br/>412.5 Methods for Limiting Water Temperature Discharged to Bathtubs --<br/>412.10 Methods for Temperature Limitation at Head Shampoo Sinks and Footbaths --<br/>419.5 Tempered Water for Public Hand-Washing Lavatories --<br/>421.3.1 Standard for Shower Waste Fittings --<br/>501.2 ASSE 1017 Temperature Actuated Mixing Valves --<br/>602.3.5 Potable Water Pumps to Comply with NSF61 --<br/>605.12.3, 605.13.6 Solder and Flux to Conform to NSF61 --<br/>606.1 Individual Tenant Water Shut-off Valve --<br/>607.1.1, 607.1.2 Water Heaters Providing Tempered Water to Fixtures --<br/>608.15.2.1 Discharge from Backflow Preventer Relief Opening --<br/>608.17.2 Backflow Device for Low Hazard Boiler Applications --<br/>609.2 Two Water Service Pipes for Group 1-2, Condition 2 Healthcare Facilities --<br/>609.2.1 Tracer Wire for Buried Nonmetallic Water Service Piping --<br/>Table 702.3 ABS Building Sewer Pipe Standard --<br/>705.2.4, 705.10.4 PVC and ABS Push-fit DWV Fittings --<br/>708.1.6 Removable Fixture Traps Serving as Cleanouts --<br/>717, 718 Methods for Restoring Building Sewer Piping --<br/>903.1.3 Protected Outdoor Vent Termination Method --<br/>915.1 Food Waste Disposers on Combination Waste and Vent Systems --<br/>1002.1 Direct Connection to Hydromechanical Grease Interceptor --<br/>1002.4.1.5 Fixture Drains Serving as a Trap Priming Method --<br/>1102.6 Roof Drains to be Tested and Rated for Flow --<br/>1106.2.1 Rainfall Rate Conversion Method --<br/>1202.1 Nonflammable Medical Gas Systems --<br/>1301.1 Nonpotable Rainwater Standard Alternative --
Formatted contents note SIGNIFICANT CHANGES TO THE International Mechanical Code --<br/>PART 2 International Mechanical Code --<br/>Chapters 1 through 15 --<br/>307.2.1.1 Condensate Discharge --<br/>401.2, 403.1 Mechanical Ventilation for Dwelling Units --<br/>401.4, 501.3.1 Intake Opening and Exhaust Outlet Locations --<br/>Table 403.3.1.1 Recirculation of Mechanical Exhaust Prohibited --<br/>403.3.1.3 Demand Controlled Ventilation --<br/>403.3.2.1 Outdoor Air for Dwelling Units --<br/>502.20 Manicure and Pedicure Station Exhaust System --<br/>504.4.1 Termination Location for Dryer Exhaust --<br/>506.3.7 Factory-Built Grease Duct Slope --<br/>507.1 Smoker Ovens with Integral Exhaust --<br/>514.2 Energy Recovery Ventilation Systems --<br/>602.2.1.8 Pipe and Duct Insulation Within Plenums --<br/>607.5.2 Duct Penetrations of Fire Barriers --<br/>607.5.5 Subducts Penetrating Shaft Enclosures --<br/>608.1, 403.3.1.5 Ventilation Air Distribution --<br/>801.21 Blocked Vent Switch for Oil-Fired Appliance --<br/>905.1 Wood-Burning Residential Hydronic Heaters --<br/>929 Unvented Alcohol Fuel-Burning Decorative Appliances --<br/>1101 through 1108 Ammonia Refrigeration Systems --<br/>1105.9 Machinery Room Means of Egress --<br/>1107 through 1110 Refrigerant Piping --
Formatted contents note SIGNIFICANT CHANGES TO THE International Fuel Gas Code --<br/>PART 3 International Fuel Gas Code Chapters 1 through 8 --<br/>202 Definition of Point of Delivery --<br/>307.2 Concealed Condensate Piping --<br/>402.7, 202 Press-Connect Joint --<br/>403.8.3 Threaded Joint Sealing --<br/>404.5 Fittings in Concealed Locations --<br/>503.5.6.1 Chimney Lining --<br/>503.8 Venting System Terminal Clearances --<br/>503.10.7 Vent Connector Junctions --<br/>614.7 Clothes Dryer Makeup Air --<br/>618.6 Return Air from Mechanical Room --<br/>623.2 Commercial Cooking Appliances --<br/><br/>
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 151828
Topical term or geographic name entry element Plumbing
General subdivision Standards
9 (RLIN) 1263
Topical term or geographic name entry element Building
General subdivision Mechanical equipment
-- Standards
9 (RLIN) 298214
Topical term or geographic name entry element Gas fitting
General subdivision Standards
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 298486
Personal name Gress, Gregg
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Libro
Classification part TH6123
Call number prefix Referencia
Call number suffix G73 2020
Existencias
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Source of acquisition Cost, normal purchase price Total Checkouts Full call number Barcode Date last seen Copy number Cost, replacement price Price effective from Koha item type
    Library of Congress Classification     CARIBET Biblioteca Arquitectura CARIBET Biblioteca Arquitectura Colección de Referencia CARIBET 11/06/2021 Amazon 50.00   Referencia TH6123 G73 2020 91000000064493 08/07/2021 1 60.00 11/06/2021 Libro Referencia CARIBET
logopucpr-y-vive

Contáctanos

¡Queremos saber de ti!

Tel. 787.841.2000 Ext. 1801

bibliotecavaldes@pucpr.edu

⁣Búscanos en las redes

© 2026 Desarrollado por Ignite Online • All Rights Reserved • Powered by Koha.