Detalles MARC
| 000 -LEADER |
| fixed length control field |
16792nam a22003617a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
pucpr |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20210610193151.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
s20202021 a f 001 0 eng |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
| International Standard Book Number |
9781609839550 |
|
| International Standard Book Number |
1609839552 |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
pucpr |
| Language of cataloging |
eng |
| Transcribing agency |
pucpr |
| Modifying agency |
pucpr |
| Description conventions |
rda |
| 049 ## - LOCAL HOLDINGS |
| Holding library |
CARIBET |
| 050 00 - LIBRARY OF CONGRESS CALL NUMBER |
| Classification number |
KF5701 |
| Item number |
I524 2020 |
| 082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER |
| Classification number |
343.07869 |
| 110 2# - MAIN ENTRY--CORPORATE NAME |
| 9 (RLIN) |
297410 |
| Corporate name or jurisdiction name as entry element |
International Code Council |
| 245 10 - TITLE STATEMENT |
| Title |
IBC 2021 : |
| Remainder of title |
International Building Code / |
| Statement of responsibility, etc. |
International Code Council. |
| Medium |
txt |
| 246 3# - VARYING FORM OF TITLE |
| Title proper/short title |
2021 International building code. |
|
| Title proper/short title |
2021 IBC. |
|
| Title proper/short title |
Twenty twenty-one International Building Code. |
| 264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
| Place of production, publication, distribution, manufacture |
Country Club Hills : |
| Name of producer, publisher, distributor, manufacturer |
ICC Publications, |
| Date of production, publication, distribution, manufacture, or copyright notice |
2020. |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
1 volume (various pagings) : |
| Other physical details |
ill.; |
| Dimensions |
28 cm. |
| Type of unit |
book |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| Content type code |
txt |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
unmediaded |
| Media type code |
n |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
volume |
| Carrier type code |
nc |
| 500 ## - GENERAL NOTE |
| General note |
Includes index. |
| 505 ## - FORMATTED CONTENTS NOTE |
| Formatted contents note |
Scope and application --<br/>101 Scope and General Requirements --<br/>102 Applicability --<br/>Administration and Enforcement --<br/>103 Code Compliance Agency --<br/>104 Duties and Powers of Building Official --<br/>105 Permits --<br/>106 Floor and Roof Design Loads --<br/>107 Construction Documents --<br/>108 Temporary Structures and Uses --<br/>109 Fees --<br/>110 Inspections --<br/>111 Certificate of Occupancy --<br/>112 Service Utilities --<br/>113 Means of Appeals --<br/>114 Violations --<br/>115 Stop Work Order --<br/>116 Unsafe Structures and Equipment --<br/>Definitions --<br/>201 General --<br/>202 Definitions --<br/>Occupancy classification and use --<br/>301 Scope --<br/>302 Occupancy Classification and Use Designation --<br/>303 Assembly Group A --<br/>304 Business Group B --<br/>305 Educational Group E --<br/>306 Factory Group F --<br/>307 High-hazard Group H --<br/>308 Institutional Group I --<br/>309 Mercantile Group M --<br/>310 Residential Group R --<br/>311 Storage Group S --<br/>312 Utility and Miscellaneous Group U --<br/>Special detailed requirements based on occupancy and use --<br/>401 Scope --<br/>402 Covered Mall and Open Mall Buildings --<br/>403 High-rise Buildings --<br/>404 Atriums --<br/>405 Underground Buildings --<br/>406 Motor-vehicle-related Occupancies --<br/>407 Group 1-2 --<br/>408 Group 1-3 --<br/>409 Motion Picture Projection Rooms --<br/>410 Stages, Platforms and Technical Production Areas --<br/>411 Special Amusement Areas --<br/>412 Aircraft-related Occupancies -- <br/>413 Combustible Storage --<br/>414 Hazardous Materials --<br/>415 Groups H-1, H-2, H-3, H-4 and H-5 --<br/>416 Spray Application of Flammable Finishes --<br/>417 Drying Rooms --<br/>418 Organic Coatings --<br/>419 Artificial Decorative Vegetation --<br/>420 Groups 1-1, R-1, R-2, R-3 and R-4 -- <br/>421 Hydrogen Fuel Gas Rooms --<br/>422 Ambulatory Care Facilities --<br/>423 Storm Shelters --<br/>424 Play Structures --<br/>425 Hyperbaric Facilities --<br/>426 Combustible Dusts, Grain Processing and Storage --<br/>427 Medical Gas Systems --<br/>428 Higher Education Laboratories --<br/>General building heights and areas --<br/>501 General --<br/>502 Building Address --<br/>503 General Building Height and Area Limitations --<br/>504 Building Height and Number of Stories --<br/>505 Mezzanines and Equipment Platforms --<br/>506 Building Area --<br/>507 Unlimited Area Buildings --<br/>508 Mixed Use and Occupancy -- <br/>509 Incidental Uses --<br/>510 Special Provisions --<br/>Types of construction --<br/>601 General --<br/>602 Construction Classification --<br/>603 Combustible Material in Types I and II Construction --<br/>Fire and smoke protection features --<br/>701 General --<br/>702 Multiple-use Fire Assemblies --<br/>703 Fire-resistance Ratings and Fire Tests --<br/>704 Fire-resistance Rating of Structural Members --<br/>705 Exterior Walls --<br/>706 Fire Walls --<br/>707 Fire Barriers --<br/>708 Fire Partitions --<br/>709 Smoke Barriers --<br/>710 Smoke Partitions --<br/>711 Floor and Roof Assemblies --<br/>712 Vertical Openings --<br/>713 Shaft Enclosures --<br/>714 Penetrations --<br/>715 Joints and Voids --<br/>716 Opening Protectives --<br/>717 Ducts and Air Transfer Openings --<br/>718 Concealed Spaces --<br/>719 Fire-resistance Requirements for Plaster --<br/>720 Thermal- and Sound-insulating Materials --<br/>721 Prescriptive Fire Resistance --<br/>722 Calculated Fire Resistance --<br/>Interior finishes --<br/>801 Scope --<br/>802 General --<br/>803 Wall and Ceiling Finishes --<br/>804 Interior Floor Finish --<br/>805 Combustible Materials in Types I and II Construction --<br/>806 Decorative Materials and Trim --<br/>807 Insulation --<br/>808 Acoustical Ceiling Systems --<br/>Fire protection and life safety systems --<br/>901 General --<br/>902 Fire Pump and Riser Room Size --<br/>903 Automatic Sprinkler Systems --<br/>904 Alternative Automatic Fire-extinguishing Systems --<br/>905 Standpipe Systems --<br/>906 Portable Fire Extinguishers --<br/>907 Fire Alarm and Detection Systems --<br/>908 Emergency Alarm Systems --<br/>909 Smoke Control Systems --<br/>910 Smoke and Heat Removal --<br/>911 Fire Command Center --<br/>912 Fire Department Connections --<br/>913 Fire Pumps --<br/>914 Emergency Responder Safety Features --<br/>915 Carbon Monoxide Detection --<br/>916 Gas Detection Systems --<br/>917 Mass Notification Systems --<br/>918 Emergency Responder Communication Coverage --<br/>Means of egress --<br/>1001 Administration --<br/>1002 Maintenance and Plans --<br/>1003 General Means of Egress --<br/>1004 Occupant Load --<br/>1005 Means of Egress Sizing --<br/>1006 Number of Exits and Exit Access Doorways --<br/>1007 Exit and Exit Access Doorway Configuration --<br/>1008 Means of Egress Illumination --<br/>1009 Accessible Means of Egress --<br/>1010 Doors. Gates and Turnstiles --<br/>1011 Stairways --<br/>1012 Ramps --<br/>1013 Exit Signs --<br/>1014 Handrails --<br/>1015 Guards --<br/>1016 Exit Access --<br/>1017 Exit Access Travel Distance --<br/>1018 Aisles --<br/>1019 Exit Access Stairways and Ramps --<br/>1020 Corridors --<br/>1021 Egress Balconies --<br/>1022 Exits --<br/>1023 Interior Exit Stairways and Ramps --<br/>1024 Exit Passageways --<br/>1025 Luminous Egress Path Markings --<br/>1026 Horizontal Exits --<br/>1027 Exterior Exit Stairways and Ramps --<br/>1028 Exit Discharge --<br/>1029 Egress Courts --<br/>1030 Assembly --<br/>1031 Emergency Rescape and Rescue --<br/>Accessibility --<br/>1101 General --<br/>1102 Compliance --<br/>1103 Scoping Requirements --<br/>1104 Accessible Route --<br/>1105 Accessible Entrances --<br/>1106 Parking and Passenger Loading Facilities --<br/>1107 Motor-vehicle-related Facilities --<br/>1108 Dwelling Units and Sleeping Units --<br/>1109 Special Occupancies --<br/>1110 Other Features and Facilities --<br/>1111 Recreational Facilities --<br/>1112 Signage --<br/>Interior environment --<br/>1201 General --<br/>1202 Ventilation --<br/>1203 Temperature Control --<br/>1204 Lighting --<br/>1205 Yards or Courts --<br/>1206 Sound Transmission --<br/>1207 Enhanced Classroom Acoustics --<br/>1208 Interior Space Dimensions --<br/>1209 Access to Unoccupied Spaces --<br/>1210 Toilet and Bathroom Requirements --<br/>Energy efficiency --<br/>1301 General --<br/>Exterior walls --<br/>1401 General --<br/>1402 Performance Requirements --<br/>1403 Materials --<br/>1404 Installation of Wall Coverings --<br/>1405 Combustible Materials on the Exterior Side of Exterior Walls --<br/>1406 Metal Composite Materials (MCM) --<br/>1407 Exterior Insulation and Finish Systems (EIFS) --<br/>1408 High-pressure Decorative Exterior-grade Compact Laminates (HPL) --<br/>1409 Plastic Composite Decking --<br/>Roof assemblies and rooftop structures --<br/>1501 General --<br/>1502 Roof Drainage --<br/>1503 Weather Protection --<br/>1504 Performance Requirements --<br/>1505 Fire Classification --<br/>1506 Materials --<br/>1507 Requirements for Roof Coverings --<br/>1508 Roof Insulation --<br/>1509 Roof Coatings --<br/>1510 Radiant Barriers Installed Above Deck --<br/>1511 Rooftop Structures --<br/>1512 Reroofing --<br/>Structural design --<br/>1601 General --<br/>1602 Notations --<br/>1603 Construction Documents --<br/>1604 General Design Requirements --<br/>1605 Load Combinations --<br/>1606 Dead Loads --<br/>1607 Live Loads --<br/>1608 Snow Loads --<br/>1609 Wind Loads --<br/>1610 Soil Loads and Hydrostatic Pressure --<br/>1611 Rain Loads --<br/>1612 Flood Loads --<br/>1613 Earthquake Loads --<br/>1614 Atmospheric Ice Loads --<br/>1615 Tsunami Loads --<br/>1616 Structural Integrity --<br/>Special Inspections and tests --<br/>1701 General --<br/>1702 New Materials --<br/>1703 Approvals --<br/>1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation --<br/>1705 Required Special Inspections and Tests --<br/>1706 Design Strengths of Materials --<br/>1707 Alternative Test Procedure --<br/>1708 In-situ Load Tests --<br/>1709 Preconstruction Load Tests --<br/>Soils and foundations --<br/>1801 General --<br/>1802 Design Basis --<br/>1803 Geotechnical Investigations --<br/>1804 Excavation, Grading and Fill --<br/>1805 Dampproofing and Waterproofing --<br/>1806 Presumptive Load-bearing Values of Soils --<br/>1807 Foundation Walls, Retaining Walls and Embedded Posts and Poles --<br/>1808 Foundations --<br/>1809 Shallow Foundations --<br/>1810 Deep Foundations --<br/>Concrete --<br/>1901 General --<br/>1902 Coordination of Terminology --<br/>1903 Specifications for Tests and Materials --<br/>1904 Durability Requirements --<br/>1905 Modifications to ACI 318 --<br/>1906 Footings for Light-frame Construction --<br/>1907 Minimum Slab Provisions --<br/>1908 Shotcrete --<br/>Aluminum --<br/>2001 General --<br/>2002 Materials --<br/>Masonry --<br/>2101 General --<br/>2102 Notations -- <br/>2103 Masonry Construction Materials --<br/>2104 Construction --<br/>2105 Quality Assurance --<br/>2106 Seismic Design --<br/>2107 Allowable Stress Design --<br/>2108 Strength Design of Masonry --<br/>2109 Empirical Design of Adobe Masonry --<br/>2110 Glass Unit Masonry --<br/>2111 Masonry Fireplaces --<br/>2112 Masonry Heaters --<br/>2113 Masonry Chimneys --<br/>2114 Dry-stack Masonry --<br/>Steel --<br/>2201 General --<br/>2202 Identification of Steel for Structural Purposes --<br/>2203 Protection of Steel for Structural Purposes --<br/>2204 Connections --<br/>2205 Structural Steel --<br/>2206 Composite Structural Steel and Concrete Structures --<br/>2207 Steel Joists --<br/>2208 Steel Cable Structures --<br/>2209 Steel Storage Racks --<br/>2210 Cold-formed Steel --<br/>2211 Cold-formed Steel Light-frame Construction --<br/>Wood --<br/>2301 General --<br/>2302 Design Requirements --<br/>2303 Minimum Standards and Quality --<br/>2304 General Construction Requirements --<br/>2305 General Design Requirements for Lateral Force-resisting Systems --<br/>2306 Allowable Stress Design --<br/>2307 Load and Resistance Factor Design --<br/>2308 Conventional Light-frame Construction --<br/>2309 Wood Frame Construction Manual --<br/>Glass and glazing --<br/>2401 General --<br/>2402 Glazing Replacement --<br/>2403 General Requirements for Glass --<br/>2404 Wind, Snow, Seismic and Dead Loads on Glass --<br/>2405 Sloped Glazing and Skylights --<br/>2406 Safety Glazing --<br/>2407 Glass in Handrails and Guards --<br/>2408 Glazing in Athletic Facilities --<br/>2409 Glass in Walkways, Elevator Hoistways and Elevator Cars --<br/>Gypsum board, gypsum panel products and plaster --<br/>2501 General --<br/>2502 Performance --<br/>2503 Inspection --<br/>2504 Vertical and Horizontal Assemblies --<br/>2505 Shear Wall Construction --<br/>2506 Gypsum Board and Gypsum Panel Product Materials --<br/>2507 Lathing and Plastering --<br/>2508 Gypsum Construction -- <br/>2509 Showers and Water Closets --<br/>2510 Lathing and Furring for Cement Plaster (Stucco) --<br/>2511 Interior Plaster --<br/>2512 Exterior Plaster -- <br/>2513 Exposed Aggregate Plaster --<br/>2514 Reinforced Gypsum Concrete --<br/>Plastic --<br/>2601 General --<br/>2602 Finish and Trim --<br/>2603 Foam Plastic Insulation --<br/>2604 Interior Finish and Trim --<br/>2605 Plastic Veneer --<br/>2606 Light-transmitting Plastics --<br/>2607 Light-transmitting Plastic Wall Panels --<br/>2608 Light-transmitting Plastic Glazing --<br/>2609 Light-transmitting Plastic Roof Panels --<br/>2610 Light-transmitting Plastic Skylight Glazing --<br/>2611 Light-transmitting Plastic Interior Signs --<br/>2612 Plastic Composites --<br/>2613 Fiber-reinforced Polymer --<br/>2614 Reflective Plastic Core Insulation --<br/>Electrical --<br/>2701 General --<br/>2702 Emergency and Standby Power Systems --<br/>Mechanical systems --<br/>2801 General --<br/>Plumbing systems --<br/>2901 General --<br/>2902 Minimum Plumbing Facilities --<br/>2903 Installation of Fixtures --<br/>Elevators and conveying systems --<br/>3001 General --<br/>3002 Hoistway Enclosures --<br/>3003 Emergency Operations --<br/>3004 Conveying Systems --<br/>3005 Machine Rooms --<br/>3006 Elevator Lobbies and Hoistway Opening Protection --<br/>3007 Fire Service Access Elevator --<br/>3008 Occupant Evacuation Elevators --<br/>Special construction --<br/>3101 General --<br/>3102 Membrane Structures --<br/>3103 Temporary Structures --<br/>3104 Pedestrian Walkways and Tunnels --<br/>3105 Awnings and Canopies --<br/>3106 Marquees --<br/>3107 Signs --<br/>3108 Telecommunication and Broadcast Towers --<br/>3109 Swimming Pools, Spas and Hot Tubs --<br/>3110 Automatic Vehicular Gates --<br/>3111 Solar Energy Systems --<br/>3112 Greenhouses --<br/>3113 Relocatable Buildings --<br/>3114 Public Use Restroom Buildings in Flood Hazard Areas --<br/>3115 Intermodal Shipping Containers --<br/>Encroachments into the public right-of-way --<br/>3201 General --<br/>3202 Encroachments --<br/>Safeguards during construction --<br/>3301 General --<br/>3302 Construction Safeguards --<br/>3303 Demolition --<br/>3304 Site Work --<br/>3305 Sanitary --<br/>3306 Protection of Pedestrians --<br/>3307 Protection of Adjoining Property --<br/>3308 Temporary Use of Streets, Alleys and Public Property --<br/>3309 Fire Extinguishers --<br/>3310 Means of Egress --<br/>3311 Standpipes --<br/>3312 Automatic Sprinkler System --<br/>3313 Water Supply for Fire Protection --<br/>3314 Fire Watch During Construction --<br/>Reserved --<br/>Referenced standards --<br/>Appendix A. Employee qualifications --<br/>A101 Building Official Qualifications --<br/>A102 Referenced Standards --<br/>Appendix B. Board of Appeals --<br/>B101 General --<br/>Appendix C. Group U - Agricultural buildings --<br/>C101 General --<br/>C102 Allowable Height and Area --<br/>C103 Mixed Occupancies --<br/>C104 Exits --<br/>Appendix D. Fire districts --<br/>D101 General --<br/>D102 Building Restrictions --<br/>D103 Changes to Buildings --<br/>D104 Buildings Located Partially in the Fire District --<br/>D105 Exceptions to Restrictions in Fire District --<br/>D106 Referenced Standards --<br/>Appendix E. Supplementary accessibility requirements --<br/>E101 General --<br/>E102 Definitions --<br/>E103 Accessible Route --<br/>E104 Special Occupancies --<br/>E105 Other Features and Facilities --<br/>E106 Telephones --<br/>E107 Signage --<br/>E108 Bus Stops --<br/>E109 Transportation Facilities and Stations --<br/>E110 Airports --<br/>E111 Referenced Standards --<br/>Appendix F. Rodentproofing --<br/>F101 General --<br/>Appendix G. Flood-resistant construction --<br/>G101 Administration --<br/>G102 Definitions --<br/>G103 Applicability --<br/>G104 Powers and Duties --<br/>G105 Permits --<br/>G106 Variances -- <br/>G107 Subdivisions -- <br/>G108 Site Improvement --<br/>G109 Manufactured Homes --<br/>G110 Recreational Vehicles --<br/>G111 Tanks --<br/>G112 Other Building Work --<br/>G113 Temporary Structures and Temporary Storage --<br/>G114 Utility and Miscellaneous Group U --<br/>G115 Referenced Standards --<br/>Appendix H. Signs --<br/>H101 General --<br/>H102 Definitions --<br/>H103 Location --<br/>H104 Identification --<br/>H105 Design and Construction --<br/>H106 Electrical --<br/>H107 Combustible Materials --<br/>H108 Animated Devices --<br/>H109 Ground Signs --<br/>H110 Roof Signs --<br/>H111 Wall Signs --<br/>H112 Projecting Signs --<br/>H113 Marquee Signs --<br/>H114 Portable Signs --<br/>H115 Thickness of Signs --<br/>H116 Referenced Standards --<br/>Appendix I. Patio covers --<br/>I101 General --<br/>I102 Definition --<br/>I103 Exterior Walls and Openings --<br/>I104 Height --<br/>I105 Structural Provisions --<br/>Appendix J. Grading --<br/>J101 General --<br/>J102 Definitions --<br/>J103 Permits Required --<br/>J104 Permit Application and Submittals --<br/>J105 Inspections --<br/>J106 Excavations --<br/>J107 Fills --<br/>J108 Setbacks --<br/>J109 Drainage and Terracing --<br/>J110 Erosion Control --<br/>J111 Referenced Standards --<br/>Appendix K. Administrative provisions --<br/>K101 General --<br/>K102 Applicability --<br/>K103 Permits --<br/>K104 Construction Documents --<br/>K105 Alternative Engineered Design --<br/>K106 Required Inspections --<br/>K107 Prefabricated Construction --<br/>K108 Testing --<br/>K109 Reconnection --<br/>K110 Condemning Electrical Systems --<br/>K111 Electrical Provisions --<br/>Appendix L. Earthquake recording instrumentation --<br/>L101 General --<br/>Appendix M. Tsunami-generated flood hazards --<br/>M101 Refuge Structures for Vertical Evacuation from Tsunami-generated Flood Hazards --<br/>M102 Referenced Standards --<br/>Appendix N. Replicable buildings --<br/>N101 Administration --<br/>N102 Definitions --<br/>N103 Replicable Design Requirements --<br/>N104 Replicable Design Submittal Requirements --<br/>N105 Review and Approval of Replicable Design --<br/>N106 Site-specific Application of Approved Replicable Design --<br/>N107 Site-specific Review and Approval of Replicable Design --<br/>Appendix 0 Performance-based application.<br/>0101 General --<br/>Index. |
| 650 00 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
Standards, Engineering. |
| 9 (RLIN) |
173751 |
| Source of heading or term |
Local |
|
| Topical term or geographic name entry element |
Construction industry |
| General subdivision |
Standards. |
| 9 (RLIN) |
79928 |
| Source of heading or term |
Local |
|
| Topical term or geographic name entry element |
Building laws |
| 9 (RLIN) |
66563 |
| Source of heading or term |
Local |
|
| Topical term or geographic name entry element |
Building |
| General subdivision |
Superintendence |
| 9 (RLIN) |
1263 |
| Source of heading or term |
LEMB |
|
| Topical term or geographic name entry element |
Architecture |
| General subdivision |
Standards. |
| 9 (RLIN) |
54081 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Library of Congress Classification |
| Koha item type |
Libro |
| Classification part |
KF5701 |
| Call number prefix |
Referencia |
| Call number suffix |
I524 2020 |